background image

DC-1023 

- 12 - 

8/5/2010 

  

 

 

Your best option for Proximity Access Control

 

For additional information, please visit AWID’s Web site 

www.awid.com

.  For technical 

support questions, visit 

www.awid.com/support

, or call 

+1-408-825-1100

 from 8:00 a.m. 

to 5:00 p.m. Pacific Time (GMT - 8 hrs). 

 

 

8 Patents 

and 

Approvals 

AWID products are covered by United States patent #5594384.   
 
AWID logo is a registered trademark of Applied Wireless Identifications Group, Inc. 
 
Where required, AWID’s products are approved by the appropriate regulatory agencies: 
 

U. S. Federal Communications Commission:   Part 15 
Underwriter 

Laboratory: 

    

Designed to Comply with:   

 

 

CE, UL, VDE, BZT, DTI & PTT 

 
 

Содержание SENTINEL-PROX DK-1025

Страница 1: ...DC 1023 1 8 5 2010 Your best option for Proximity Access Control SENTINEL PROX DK 1025 Dual frequencies RFID Reader Users Manual 041420...

Страница 2: ...ese limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio fre...

Страница 3: ...allation Practices 6 3 3 Metal Mounting 6 3 4 General Wiring Requirements 7 3 5 Power Supply 7 3 6 Grounding 7 3 7 Wiring Diagrams 7 4 INSTALLATION PROCEDURE 9 4 1 Parts List 9 4 2 Installation Steps...

Страница 4: ...DC 1023 4 8 5 2010 Your best option for Proximity Access Control REVISION HISTORY Version No Revised By Date Sections Affected Remarks 1 0 Z Wang 7 21 2010 All Initial version...

Страница 5: ...ang box o Permanently sealed electronics for indoor outdoor application o UV stabilized plastic housing 1 3 SUGGESTED APPLICATIONS o Access Control o Time Attendance o Asset Management o RFID 2 SPECIF...

Страница 6: ...on interruptible power supplies AC switching relays light dimmers CRT s induction heater ultrasonic welder etc Do not bundle the reader wires together in one conduit with the AC power cables lock powe...

Страница 7: ...der When installing the Reader it is crucial to assure that the earth ground is the best ground available If you elect to use the AC main power ground conduct a test by measuring its resistance relati...

Страница 8: ...DC 1023 8 8 5 2010 Your best option for Proximity Access Control Figure 1 Wiring Diagram for Wiegand Output Format Figure 2 Wiring Diagram for RS232 Output Format...

Страница 9: ...32 Output Format 4 INSTALLATION PROCEDURE Check to verify that every item listed under Section 5 1 of this manual is present before starting the installation 4 1 PARTS LIST a Installation sheet P N xx...

Страница 10: ...y placing the card in front of the reader after the LED turned RED If the Panel did not right it must be powered off on to re initialize 4 4 MOUNTING 1 Connect the remaining wires to the Panel 2 Mount...

Страница 11: ...ay from electromagnetic interference sources When troubleshooting try to identify the source of the problem to a unit level Is the problem originating from the panel Or is the problem originating from...

Страница 12: ...00 from 8 00 a m to 5 00 p m Pacific Time GMT 8 hrs 8 Patents and Approvals AWID products are covered by United States patent 5594384 AWID logo is a registered trademark of Applied Wireless Identifica...