3.2 INSTALLATION 

 

 

 

3.2.1 Site location 

 

 

 

 

 

The professional installer should select a suitable indoor location for set-up 
of the reader, antennas, and PC.  An AC mains socket should be available 
to plug in the readers 12V supply. 
Antennas should not be mounted on metal, or mounted within close 
proximity of devices generating large amounts of electro-magnetic 
interference i.e. electric motors.  

 

 

 

3.2.2 Reader Location  

 

Position reader, RF cables, power cables, and communication cables, so 
all can easily reached the proper connections on the reader.  The reader 
should be mounted on a flat surface, horizontal or vertical, by placing bolts 
or screws through predrilled holes near the corners of the reader. 

 

3.2.3 Antenna Connections 

 

The MPR-5005 reader can be connected with one of two antenna 
configurations:  Single antenna (MPR-5007) or dual antenna (MPR-5011A 
+ MPR-5011B).  Both have BNC RF connectors. 

 

MPR-5007 Single Antenna: Plug RF connector from antenna into the RF 
connector on the reader. 
 
MPR-5011A/B Dual Antenna: Connect the two antennas together via one 
6-foot RF cable.  Labels on each antenna direct connection route.  
Connect the antenna pair to the reader by using the additional 6-foot RF 
cable, once again, following labels on antennas.  

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

AWID PROPRIETARY

 

Содержание MPR-5005

Страница 1: ...MPR 5005 Page 1 Doc 041326 MPR 5005 125kHz Reader Installation Operation Manual 041326 AWID PROPRIETARY...

Страница 2: ...pment has been tested and found to be in compliance with the limits for FCC Part 15 Class A digital device These limits are designed to provide reasonable protection against harmful interference when...

Страница 3: ...a for prolonged periods may safely remain at least 23 cm 9 in in an uncontrolled environment from the reader s surface Observe FCC OET Bulletin 56 Hazards of radio frequency and electromagnetic fields...

Страница 4: ...UIDELINES 8 3 1 Parts List 8 3 2 Installation 9 3 2 1 Site location 9 3 2 2 Reader Location 9 3 2 3 Antenna Connections 9 3 3 Operation 10 4 SOFTWARE 11 NOTE READ AND USE THIS MANUAL NOTE ONLY A TRAIN...

Страница 5: ...ductance is 220uH Reader provides all controls and RF energy to activate the transponder Two different antenna configurations can be connected to the readers BNC connector The reader checks the receiv...

Страница 6: ...ission Miller Decoding Receive Manchester Encoding Transmit Modulation ASK Reader Antenna Size MPR 5007 648mm x 546mm x 25 4mm MPR 5011A B 508mm x 254mm x 37mm Antenna Base material ABS PVC Antenna Tu...

Страница 7: ...RS232 Connector Pin Assignment Pin Function 1 2 RS232 Tx 3 RS232 Rx 4 5 Ground o Please refer to document MPR 5005 RS232 Interface for command listings TCP IP Interface o Please refer to Document MPR...

Страница 8: ...na paired with MPR 5011B Antenna o MPR 5011B Dual Antenna paired with MPR 5011A Antenna o Two 6 foot long BNC RF cables for connecting Dual Antennas o 12V power supply Additional equipment needed o Cr...

Страница 9: ...er connections on the reader The reader should be mounted on a flat surface horizontal or vertical by placing bolts or screws through predrilled holes near the corners of the reader 3 2 3 Antenna Conn...

Страница 10: ...reader to initialize 6 Run RFTagger exe on PC RFTagger is HP proprietary user interface software 7 Connect to reader In the Reader menu select Set IP A box will pop up asking for the readers IP addres...

Страница 11: ...ality of the RFID Tag The tag has different blocks and pages of memory that can be read and written to These other options are as follows o FIND TAGS o READ BLOCK o READ PAGE o WRITE PAGE o WRITE READ...

Отзывы: