USER’S MANUAL
7
Ⅷ
. TROUBLE SHOOTING
1.
Producing water slowly:
Check the temperature and humidity suitable the machine working.
Check the air mesh if serious dust on it. If so, please clean.
Check enough place between the machine front and back.
Check the power supply voltage in the normal range
2.
Power connection, the machine does not work
Check the machine power connection
Ⅸ
. FAULT CODE
Fault
Fault reasons
Fault
Fault reasons
E1
Evaporator temperature sensor fault
E6
No. 1 Compressor low voltage protection
E2
The temperature sensor fault
E7
No. 2 Compressor low voltage protection
E3
Sequence protection
n
E8
No. 3 Compressor low voltage protection
E4
Short sequence protection
E9
No. 4 Compressor low voltage protection
Ⅹ
: TECHNICAL SPECIFICATIONS
KM-250L
power
380V/50Hz
220V/60Hz
rated input
4.8KW
4.8KW
maximum
current
9.5A
19.3A
production
capacity
250L/D
standard
condition
RH: 75% / T: 27
℃
normal condition
RH: 40%-90% / T: 15
℃
-35
℃