INSTALLATION

 

Fitting the Hood canopy 

BEFORE FITTING THE HOOD TO THE WALL UNIT, PROCEED AS FOLLOWS: 

 
•  Remove grease filters. 
 

 
 

 
 
•  Disconnect the wires to the Commands at the connectors. 
 
 
•  Disconnect the wires to the Light at the connectors. 

 
 

 
•  The Hood can be installed directly 

on the underside of the wall unit 
(Minimum 650 mm from the 
Cooker Hob). 

•  Create an opening in the bottom of 

the wall unit, as shown. 

•  Insert the hood until the side sup-

ports snap into place. 

 
 
 
 
 
 
 
•  Lock in position by tightening the screws 

Vf

 from underneath the 

hood. 

 
 
•  Re-connect the wires to the Commands and Light, replace the metal grease filter. 

 

273

20

584 - 684 - 884

Содержание PPS902SI

Страница 1: ...Instructions Manual PPS902SI ...

Страница 2: ...2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 6 INSTALLATION 7 USE 9 MAINTENANCE 10 EN ...

Страница 3: ...or hood to exhaust ducts carrying combustion fumes boilers fireplaces etc If the extractor is used in conjunction with non electrical appliances e g gas burning appliances a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean ai...

Страница 4: ... to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overheated oil can burst into flames Do not flambè under the range hood risk of fire This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowled...

Страница 5: ... heavy usage Failure to carry out cleaning as indicated will result in a fire hazard Clean the hood using a damp cloth and a neutral liquid detergent The symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring th...

Страница 6: ... 650 mm 650 98 Components Ref Q ty Product Components 1 1 Hood Body complete with Controls Light Blower Filters 8 1 Directioned grid 9 1 Reducer Flange ø 150 120 mm 10 1 Damper ø 150 mm Ref Q ty Installation Components 12e 2 Screws 2 9 x 9 5 Q ty Documentation 1 Instruction Manual 10 9 8 12e ...

Страница 7: ...Light at the connectors The Hood can be installed directly on the underside of the wall unit Minimum 650 mm from the Cooker Hob Create an opening in the bottom of the wall unit as shown Insert the hood until the side sup ports snap into place Lock in position by tightening the screws Vf from underneath the hood Re connect the wires to the Commands and Light replace the metal grease filter 273 20 5...

Страница 8: ... clamps not supplied Remove any activated charcoal filters 9 ø120 ø150 10 10 RECIRCULATION VERSION AIR OUTLET Cut a hole ø 125 mm in any shelf that may be posi tioned over the hood Insert the reducer flange 9 on the hood body outlet Connect the flange to the outlet on the shelf over the hood by using a flexible or rigid pipe ø120 mm Fix the pipe in position using sufficient pipe clamps not supplie...

Страница 9: ... filters alarm is triggered the alarm can be reset by pressing and holding this button for approximately 3 seconds These indications are only visible when the motor is turned off FF flashes three times When the procedure terminates the indication shown previously turns off FG indicates the need to wash the metal grease filters The alarm is triggered after the Hood has been in operation for 100 wor...

Страница 10: ...ce every 2 months use or more frequently if use is particularly intensive Resetting the alarm signal Turn the Lights and the Suction motor off then disable the 24h function if enabled Press button E see the paragraph on Use Cleaning the Filters Remove the Filters one at a time pushing them towards the back of the unit and at the same time pulling downward Wash the Filters without bending them and ...

Страница 11: ...ress D and hold for approximately 5 Seconds The message FC Dot flashes twice A C Filter saturation alarm ACTIVATED The message FC Dot flashes once A C Filter saturation alarm DEACTIVATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Turn the Lights and the Suction motor off then disable the 24h function if enabled Press button E see the paragraph on Use Changing the Filter Remo...

Страница 12: ...991 0514 800_02 170719 D0003853_01 ...