Adjusting The Reduced Flame Position :
For reduced flame position the by pass screw must be loosened in transformation from
LPG to NG. In transformation from NG to LPG, the same screw must be fastened. Make
sure that the appliance is unpluged from the electric current and the gas feed is open.
Ignite the burners and leave them on in minimum position.
Remove the knobs because the screws are accesible only when the knobs are removed.
With the help of a small screwdriver fasten or loosen the by pass screw 90
0
, which makes
the flame of the burner come down to the minimum (Figure 6).
When the flame has a length of at least 4mm, the gas is well distributed. Make sure that
the flame does not die out when passing from the maximum position to the minimum
position.
!
Seal
Hose
Fitting
Hose
Fitting
Gas Hose
with Collar
Gas Pipe
Figure 4
Seal
Hose
Fitting
Gas Hose
with Collar
Gas Pipe
Mechanical
Gas Hose
Seal
Hose
Fitting
Gas Pipe
Seal
Hose
Fitting
Hose
Fitting
Mechanical
Gas Hose
Gas Pipe
Mechanical
Gas Hose
Hose
Fitting
Gas Pipe
Changing the Gas Inlet :
During connections always keep the nut on the gas manifold fixed, while rotating the counter-part.
Use spanners of appropriate size for safe connection. For all surfaces between different
components, always use the seals provided in the gas conversion kit. The seals used during
connection should also be approved to be used in gas connections. Do not use plumbing seals for
gas connections.
Remember that this appliance is ready to be connected to gas supply in the country for which it has
been produced. The main country of destination is marked on the rear cover of the appliance. If you
need to use it in another country, any of the connections in the figure below can be required.
In such a case, contact local authorities to learn the correct gas connection.
It is required to call the authorized service to be able to make the gas connections appropriately and
in compliance with safety standards.
ATTENTION! Surely do not use any match or lighter for control of gas leakage.
!
10
.
The gas inlet of this product is on the right side of the appliance. If connection point needs to be
moved to the left side of the appliance, you can request an extension pipe from your authorized
service.