15
Referance Manual
ETH-LORA-M-AX-01
LOW POWER MODE
ETH-LORA-M-AX-01 has been designed with low power mode feature to save the consumption which is vital in battery powered device. There are four
low power modes available. The module enters the low power mode after configurable delay (LPDelay) when the module is in idle state. The most
efficient mode to save the consumption is STOP Mode. However, in this mode the UART cannot be used to wake up the module. A GPIO’s P11 should
be set high by the user before sending any AT commands.
Please refer to the Module Integration Guide
document for detail of the external P11 pin location
www.avx.com/products/modules/lora-module
NOTE:
The most efficient way to avoid any communication error is systematically send a CARRIER RETURN (0x0d) and wait the module answers with
a string “OK” before sending any AT command.
In passive architecture there is one EC686 which is used for IM algorithm, while in active configuration one more EC686 is used for MCD algorithm.
The state of both EC686 can be controlled in low power mode.
Set the Low Power Mode:
Read the Low Power Mode:
LPM Mode
Entry
Wake-up
Effect on V
core
domain clocks
Effect on V
DD
domain
clocks
Voltage
regulator
Normal Mode
(0)
-
-
None
None
ON
LP Run (1)
After
parameter
LPDelay
expired
UART,
GPIO’sP11,
RTC Alarm
DEEPSLEEP
(2)
(Factory
default)
CPU CLK OFF no
effect on other
clocks or analog
clock sources, Flash
CLK OFF
In Low-Power
Mode
STOP Mode
(3)
GPIO’sP11,
RTC Alarm
All V
core
domain clock
OFF
HSI and HSE and MSI
oscillators OFF
In Low-Power
Mode
AT Command
Syntax
AT+LORA@SYS%LPMODE=<mode>[,<EC686LPState>]
Parameter
<mode >
Low Power mode
0
Disable Low Power mode.
1
Enable Low Power Run mode.
2
Enable Low Power DEEPSLEEP mode. (Factory Default mode)
3
Enable Low Power STOP mode.
[<EC686LPState >]
EC686 State in low power mode (if available)
(optional parameter)
0
Both EC686 are ON (IM and MCD)
1
Internal EC686 OFF (IM), External EC686 ON(MCD)
2
Internal EC686 ON (IM), External EC686 OFF(MCD)
3
Both EC686 are OFF (IM and MCD)
Return Value
<CR><LF>OK<CR><LF>: Operation successful.
<CR><LF>ERROR<CR><LF>: Parameters is expected or wrong parameter
Example
AT+LORA@SYS%LPMODE=3,3
Example
description
Set the low power mode to STOP mode
Both EC686 (if available) will be turn off when the device enter the STOP mode
AT Command
Syntax
AT+LORA@SYS%LPMODE?
Return Value
<CR><LF>3, 3<CR><LF>OK<CR><LF>: Operation successful.
Description
The module is using STOP mode as low power mode and the both EC686 (if available) will turn off
when device enter the low power mode
Table 5
092419
Содержание ethertronics ETH-LORA-M-AX-01
Страница 1: ...ETH LORA M AX 01 Reference Manual ...