background image

4.INSTALLATION

Connector description

The wiring cable of the PTZ camera provides connectors for power supply, video and
I/O interface

Video output
BNC

Inner Conn: 
Outer Conn: Ground

Video Output to monitor or DVR

Using optional accessories

The speed dome cameras can be connected to various optional accessories through
the standard connector types, which simplifiy the cable handling and avoids possible
mistakes. All accessories are tested for max. compatibility and best performance.

Outdoor power adaptor box
AC 230V to AC 24V

AC 24 Power

supply

RS 485

Alarm I/O

AC 230V
Power input

Indoor power adaptor
AC 230V to AC 24V

AC 230V

Power input

AC 24 Power supply

3-Axis keyboard

controller

RS 485

Telemetric control
camera setup

21”High Res.
security Monitor.

Professional Real-time
16 Channel DVR

Video signal

RS 485 cable

The telemetric control of the appliance uses Rs485  serial communication with half-
duplex transmission technology.
Depends on the cable typeand baud rate, the transmission distance could vary. The
following table shows max. distances based on cable with 0,56mm (24AWG) twisted
pair:

2400 bps

1100 m

700m

4oom

4800 bps

1700m

9600 bps

19200 bps

Baud Rate

Max. Distance

Due the environmental interferences, such as
eletromagnetic and induction fields, or number of
connected appliance on the RS-485 bus, the
transmission range may be less, e.g with cable thinner
than  than 24AWG.

4.INSTALLATION

5

6

Power
Connector

RS485
Connector
RJ-11

Alarm I/O 1

RED: AC 24V
BLACK: AC 24V

To power supply

Green:RS485+
Yellow:RS485-

To Keyboard or DVR decives for
telemetric control

RED: Alarm in  1
PINK: Alarm in  2
YELLOW:
GREEN:
BLACK: COM
WHITE: Alarm output - N.O
BLUE: Alarm output - N.C

AQUA

Alarm in  3

Alarm in  4

Alarm output - N.C2

BROWN: Alarm output - N.O2
GRAY: Alarm in  7
PURPLE: Alarm in  6
ORANGE: Alarm in  5

:

I/O interface to additional alarm sensor
or control devices

Alarm I/O 2

Some products may not be available in your country, please contact our distributor for more details

Some products may not be available in your country, please contact our distributor for more details

Содержание High Speed dome Camera Series

Страница 1: ...USER S MANUAL v 2 66 High Speed dome Camera Series ...

Страница 2: ... IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE WARNING THIS IS A CLASS A PRODUCT IN A DOMESTIC ENVIRONMENT THIS PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER MAY BE REQUIRED TO TAKE ADEQUATE MEASURES CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE...

Страница 3: ... 140 F and a humidity below 90 The input power source is 24V AC 50 60Hz and requires 2500mA outdoor models Do not expose the indoor model of dome camera to water or moisture not try to operate it in wet areas 2 FEATURES 1 2 Some products may not be available in your country please contact our distributor for more details Some products may not be available in your country please contact our distrib...

Страница 4: ...nt damages caused by high voltage pulse such as lightning strike below 1500 This appliance meets the Ip66 standard for water and dust proof Do not install the in door model for out door application which is not designed with water protection Make sure that the installation is protected from long time water drop or spatter which may damage the appliance Make sure that the enviroment of installation...

Страница 5: ...hnology Depends on the cable typeand baud rate the transmission distance could vary The following table shows max distances based on cable with 0 56mm 24AWG twisted pair 2400 bps 1100 m 700m 4oom 4800 bps 1700m 9600 bps 19200 bps Baud Rate Max Distance Due the environmental interferences such as eletromagnetic and induction fields or number of connected appliance on the RS 485 bus the transmission...

Страница 6: ...th 120 resistor on both ends Following picture illustrates the connection methods please note that a daisy chain connection type shall not exceed 7 meters Ω 120Ω Resistor Device 2 Device 3 Device 1 120Ω Resistor RS 485 RS 485 RS 485 RS 485 Termination on Termination off Termination off How to turn on termination on the high speed dome camera The termination switch is located on the rear side of th...

Страница 7: ...After unpaking and during the installation the core unit should be installed as following Installing the core unit by pushing into the housing please note the position of connector For releasing please press the lever lock to core and pull off the unit Lever Lock Connector Interface Power LED Metal Clip WARNING Do not pull or hold the connector interface with force It is design only to connect the...

Страница 8: ... NUMBER 1 PROGRAM PATTERN RUN PATTERN CLEAR PATTERN EDIT PATTERN LABEL BACK EXIT EDIT T O U R P0 S P0 S P0 S 00 0 00 00 0 00 00 0 00 TM TM TM B A C K E X I T 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 00 0 00 Z O N E S ZONES NUMBER 1 SET LEFT LIMIT SET RIGHT LIMIT CLEAR ZONE EDIT ZONE LABEL BACK EXIT DOME LABEL OFF PRESET LABEL OFF ZOOM LABEL O ZONE LAB...

Страница 9: ...es the idle time prior to start a custom defined action park action The range is from 1 to 240 minutes This function can be deactivated by setting the minute to 0 PARK ACTION POWER UP ACTION FAN ENABLED TEMP C F the action which will be started after the idle time park time Selectable between Preset Scan Pattern Nr Tour or None defines the action which will be started after power up and self test ...

Страница 10: ...e details 15 ADVANCE SETTING1 IR CUT FILTER MAX GAIN EXPOSURE COMP Mirror Flip Enables the removal of Infrared Cutter Filter IRC also known as DAY NIGHT mode with the removal of IRC the camera turns into Black White mode and has higher sensibility to low light or IR Light in the night Selectable between On Off Auto or Time Only available on camera module with IRC function improve the image quality...

Страница 11: ... current day STATE activate AUTO TRACKING on this day START TIME set the time for activation END TIME set the time for stop the tracking SENSITIVE set the sensitivity for the detection TRAKING ZOOM activate auto zoom SET LIMIT set the max angle for the tracking TIME RUNNING DAY SUN TIME CHANNEL 1 START TIME 00 00 END TIME 00 00 RUNNING NONE BACK EXIT Clear the current preset Start Auto Tracking if...

Страница 12: ... 0 0 HUNDA 1 0 1 1 0 0 KALATEL 0 1 0 1 0 0 LILIN 1 1 0 1 0 0 MOLYNX 0 0 1 0 0 0 PANASONIC 1 1 1 0 0 0 PELCO D P 1 0 0 0 0 0 PHILIPS 0 0 0 0 0 1 SAE 0 1 0 0 0 0 SAMSUNG 0 0 0 1 0 0 SANTACHI 0 1 1 0 0 0 UNIVISION 0 1 0 0 0 1 VCL 1 1 0 0 0 0 VICON 1 0 1 0 0 0 AD 1 0 0 0 0 1 Some products may not be available in your country please contact our distributor for more details ALARM SETTING ALARM NUMBER 00...

Страница 13: ...7 Address ID 1 to 67 7 Address ID 68 to 135 ...

Страница 14: ...7 Address ID 136 to 203 177 7 Address ID 204 to 255 ...

Страница 15: ...t 0 4 150 per sec with Auto Flip Vario Speed control Proportional constant PT speed Outdoor 18X Outdoor 18x Outdoor 26x Outdoor 36x Indoor 18X Indoor 18x Indoor 26x Indoor 36x 9 Motion Tracking Note This option is only available if your Speed dome supported this function 1 Enter the OSD menu with CALL 95 2 Go to the option Function Setting Auto Tracking AUTO TRACKING DAY SUN STATE ON START TIME 00...

Отзывы: