SPECIFICATIONS
Model:
AVRF-7A-B
1
Amplitude
2
:
0 to 750 Volts (50 Ohm load required)
Rise & fall times (20%-80%):
≤ 5 ns for positive outputs,
≤ 8 ns for negative outputs
Pulse width (FWHM):
0.15 to 10 us for positive outputs,
0.15 to 5 us for negative outputs
PRF:
0 to 5 kHz
Duty cycle (max):
0.1%
Average power out (max):
11 Watts
Polarity:
Positive (-P option), negative (-N option), or both (-PN option)
Propagation delay:
≤ 150 ns (Ext trig in to pulse out)
Jitter:
± 100 ps ± 0.03% of sync delay (Ext trig in to pulse out)
Trigger required:
(external trigger mode)
Mode A: + 5 Volts, 50 ns or wider (TTL)
Mode B: + 5 Volts, PW
IN
= PW
OUT
(TTL)
Sync delay:
Variable, 0 to ± 1 second
Sync output:
+3 Volts, 100 ns, will drive 50 Ohm loads
Gate input:
Synchronous or asynchronous, active high or low, switchable.
Suppresses triggering when active.
Connectors:
Out: BNC
3
Trig, Sync, Gate: BNC
GPIB and RS-232 control
1
:
Standard on -B units.
Telnet / Ethernet control:
Optional (-TNT option).
See
http://www.avtechpulse.com/options/tnt
for details.
Power requirements:
100 - 240 Volts, 50 - 60 Hz
Dimensions: (H x W x D)
100 mm x 430 mm x 475 mm (3.9” x 17” x 18.8”)
Rack-mount kit:
Optional. Add -R5 to the model number.
Temperature range:
+5°C to +40°C
1) -B suffix indicates IEEE-488.2 GPIB and RS-232 control of amplitude, pulse width, PRF and delay. (See
http://www.avtechpulse.com/gpib
).
2) For operation at amplitudes of less than 20% of full-scale, best results will be obtained by setting the amplitude near full-scale and using external attenuators on the output.
3) Add the suffix -NC, -HN, -MHV, or -SHV to the model number to replace the standard BNC output connector with N, HN, MHV, or SHV connectors, respectively.