CONNECTING TO THE LOAD
The main output connector is a Positronic part number GG8888F1, with four
GGFIT00MS/AA high-current contacts.
The inner two contacts carry the signal, and the outer two carry the ground lines.
The supplied AV-HLZ1-100 cable or the AV-HLZA1 test load may be plugged into this
connector. Alternatively, the user may construct their own mating connector, by
ordering Positronic (www.positronic.com) part number GG8888M1, with four
GGMIT00MS/AA high-current contacts.
Note the alignment grooves. Mating connectors must be positioned appropriately.
AV-HLZ1-100 CABLE
One AV-HLZ1-100 cable is provided with the AVOZ-E3-B. One end of the cable mates
to the rear-panel OUT connector.
The cable is specially designed to have a transmission line characteristic impedance
(Z
0
) of approximately 1 Ohm, to minimize distortions and reflections.
The cable may be attached to the OUT connector simply by inserting the male end of
the cable into the OUT connector, taking care to align the alignment grooves. The jack
screws may be used to secure the cable to the connector.
An attached cable is shown below:
25
Ground
Out
Out
Ground
Alignment
grooves