MECHANICAL INFORMATION

TOP COVER REMOVAL

If necessary, the interior of the instrument may be accessed by removing the four 
Phillips screws on the top panel. With the four screws removed, the top cover may be 
slid back (and off).

 Always disconnect the power cord and allow the instrument to sit unpowered for 10 

minutes before opening the instrument. This will allow any internal stored charge to 
discharge.

There are no user-adjustable internal circuits. For repairs other than fuse replacement, 
please contact Avtech ([email protected]) to arrange for the instrument to be 
returned to the factory for repair. Service is to be performed solely by qualified service 
personnel.

 Caution: High voltages are present inside the instrument during normal operation. 

Do not operate the instrument with the cover removed.

RACK MOUNTING

A rack mounting kit is available. The -R5 rack mount kit may be installed after first 
removing the one Phillips screw on the side panel adjacent to the front handle.

ELECTROMAGNETIC INTERFERENCE

To prevent electromagnetic interference with other equipment, all used outputs should 
be connected to shielded loads using shielded coaxial cables. Unused outputs should 
be terminated with shielded coaxial terminators or with shielded coaxial dust caps, to 
prevent unintentional electromagnetic radiation. All cords and cables should be less 
than 3m in length.

20

Содержание AV-143CP

Страница 1: ...L E C T R O S Y S T E M S L T D N A N O S E C O N D W A V E F O R M E L E C T R O N I C S S I N C E 1 9 7 5 P O BOX 265 OGDENSBURG NY U S A 13669 0265 TEL 888 670 8729 USA Canada or 1 613 686 6675 In...

Страница 2: ...ace said defective item This warranty does not apply to units which have been dissembled modified or subjected to conditions exceeding the applicable specifications or ratings This warranty is the ext...

Страница 3: ...UAL CHECK 9 POWER RATINGS 9 CONNECTION TO THE POWER SUPPLY 9 PROTECTION FROM ELECTRIC SHOCK 10 ENVIRONMENTAL CONDITIONS 11 FUSES 12 AC FUSE REPLACEMENT 12 DC FUSE REPLACEMENT 13 FUSE RATINGS 13 FRONT...

Страница 4: ...LY 1 3 23 PCB 158P LOW VOLTAGE POWER SUPPLY 2 3 24 PCB 158P LOW VOLTAGE POWER SUPPLY 3 3 25 MAIN WIRING 26 PERFORMANCE CHECK SHEET 27 Manual Reference fileserver2 officefiles instructword av 143 AV 14...

Страница 5: ...into resistive loads or capacitive loads of up to 2 2 nF The output rise and fall times are 0 4 us or less SPECIFICATIONS Model AV 143CP PS AVA Output amplitude 0 to 12V Voltage Gain 6 V V Rise fall...

Страница 6: ...g Also check that your load is adequately shielded It may be necessary to enclose the load in a metal enclosure If any of the connectors on the instrument are unused they should be covered with shield...

Страница 7: ...ies to Directive 2002 96 EC categories 1 7 and 10 as stated in the Article 2 Scope section of Directive 2002 95 EC DIRECTIVE 2002 96 EC WEEE European customers who have purchased this equipment direct...

Страница 8: ...a AAD130SD 80 A switching power supply According to the manufacturer the Tamura AAD130SD 80 A has the following certifications UL60950 1 IEC60950 1 CSA C22 2 No 60950 1 EN60950 1 and is compliant with...

Страница 9: ...WER SUPPLY An IEC 320 three pronged recessed male socket is provided on the back panel for AC power connection to the instrument One end of the detachable power cord that is supplied with the instrume...

Страница 10: ...ors are prevented access and or are insulated from every connection point In some cases connections must be exposed to potential human contact Operators must be trained to protect themselves from the...

Страница 11: ...ndoor use 2 altitude up to 2 000 m 3 temperature 5 C to 40 C 4 maximum relative humidity 80 for temperatures up to 31 C decreasing linearly to 50 relative humidity at 40 C 5 Mains supply voltage fluct...

Страница 12: ...the fuses on the rear panel are shown in the figure below AC FUSE REPLACEMENT To physically access the AC fuses the power cord must be detached from the rear panel of the instrument The fuse drawer ma...

Страница 13: ...Nominal Mains Voltage Rating Case Size Recommended Replacement Part Littelfuse Part Number Digi Key Stock Number 1 2 AC 100 240V 0 5A 250V Time Delay 5 20 mm 0218 500HXP F2416 ND 3 DC N A 1 0A 250V Ti...

Страница 14: ...tput disabled for about 5 seconds after which the instrument will attempt to re enable the output i e light green for about 1 second If the overload condition persists the output will be disabled agai...

Страница 15: ...detachable power cord that is supplied with the instrument plugs into this socket 2 AC FUSE DRAWER The two fuses that protect the AC input are located in this drawer Please see the FUSES section of t...

Страница 16: ...mum output current to 650 mA approximately CAPACITIVE LOADING The AV 143CP PS AVA is designed to handle load capacitances of up to 2 2 nF Larger capacitances should be avoided as they may cause instab...

Страница 17: ...caused by the cabling and the cable s capacitance will distort the output signal and degrade the rise and fall times particularly if the signals with fast rise times are used 17...

Страница 18: ...f the AV 143CP PS AVA is 1 k Connect a cable from the SYNC connector of the signal generator to the TRIG input of an oscilloscope Set the oscilloscope to trigger externally Connect the main output of...

Страница 19: ...5 Turn on the amplifier and the signal generator 6 The Channel B waveform should increase to 12V and have a shape similar to that of the Channel A waveform 7 This completes the operational check 19...

Страница 20: ...factory for repair Service is to be performed solely by qualified service personnel Caution High voltages are present inside the instrument during normal operation Do not operate the instrument with t...

Страница 21: ...es may require replacement All fuses can be accessed from the rear panel See the FUSES section for details CLEANING If desired the interior of the instrument may be cleaned using compressed air to dis...

Страница 22: ...h a s s is g ro u n d p o s t G 1 G 2 B 1 R E D G 4 G 3 L N G X 2 C O R C O M 6 E G G 1 2 P O W E R E N T R Y M O D U L E 1 1 b 1 a 2 2 b 2 a X 1 P O W E R S W I T C H S W 3 2 5 N D C W IN D U S T R...

Страница 23: ...N D 1 5 V P O U T 3 P O U T 1 1 5 V 1 2 J 7 6 4 0 4 5 6 2 D ig i A 1 9 2 1 N D X 8 6 3 2 1 4 S S S C R E W 0 6 0 4 M P P 1 8 8 X 9 6 3 2 1 4 S S S C R E W 0 6 0 4 M P P 1 8 8 X 1 3 6 3 2 S S E X T T O...

Страница 24: ...ig i P 5 5 5 0 N D C 8 2 2 u F D i g i 4 4 5 2 8 9 6 N D L 1 M o u s e r 4 3 4 7 7 A 1 0 1 M 0 1 C 4 4 7 u F 3 5 V D i g i P 5 5 5 0 N D C 1 2 2 2 u F D i g i 4 4 5 2 8 9 6 N D L 4 M o u s e r 4 3 4 7...

Страница 25: ...A V T E C H D I S A B L E O L O W H E N C H A R G I N G S H O R T S O U T B A S E W H E N C H A R G I N G B U 1 5 V G N D 1 5 V X 1 K E Y S T O N E 6 2 1 D i g i 6 2 1 K N D R 1 5 0 I F O L O U S E S...

Страница 26: ...5 J 6 J 7 J 8 J 9 F A N J 1 0 G N D G N D G N D 2 0 A W G C J 1 2 G N D I N I N J 1 1 O U T O U T G N D H V H V O U T I N G N D G N D G N D G N D L V N C B U F N C A M P N C 1 5 V 1 5 V I N V O S N C...

Страница 27: ...PERFORMANCE CHECK SHEET 27...

Отзывы: