background image

INSTRUCTIONS

MODEL AV-110B-PS-D or AV-110G-PS-D

0 to ±200V

VARIABLE-GAIN DUAL-CHANNEL

LINEAR AMPLIFIER

SERIAL NUMBER: ____________

1

A V T E C H     E L E C T R O S Y S T E M S     L T D .

N A N O S E C O N D   W A V E F O R M   E L E C T R O N I C S

S I N C E   1 9 7 5

P.O. BOX 265

OGDENSBURG,  NY

U.S.A. 13669-0265

TEL: 888-670-8729 (USA & Canada) or +1-613-686-6675 (Intl)

FAX: 800-561-1970 (USA & Canada) or +1-613-686-6679 (Intl)

[email protected]    -    http://www.avtechpulse.com/

X

BOX 5120, LCD MERIVALE

OTTAWA, ONTARIO

CANADA    K2C 3H4

Содержание AV-110B-PS-D

Страница 1: ...C T R O S Y S T E M S L T D N A N O S E C O N D W A V E F O R M E L E C T R O N I C S S I N C E 1 9 7 5 P O BOX 265 OGDENSBURG NY U S A 13669 0265 TEL 888 670 8729 USA Canada or 1 613 686 6675 Intl FA...

Страница 2: ...ace said defective item This warranty does not apply to units which have been dissembled modified or subjected to conditions exceeding the applicable specifications or ratings This warranty is the ext...

Страница 3: ...UAL CHECK 9 POWER RATINGS 9 CONNECTION TO THE POWER SUPPLY 9 PROTECTION FROM ELECTRIC SHOCK 10 ENVIRONMENTAL CONDITIONS 11 FUSES 12 AC FUSE REPLACEMENT 12 DC FUSE REPLACEMENT 13 FUSE RATINGS 13 FRONT...

Страница 4: ...TAGE POWER SUPPLY 2 3 25 PCB 158N LOW VOLTAGE POWER SUPPLY 3 3 26 PCB 168B HIGH VOLTAGE DC POWER SUPPLY 27 MAIN WIRING 28 PERFORMANCE CHECK SHEET 29 Manual Reference fileserver officefiles instructwor...

Страница 5: ...oyed when using this instrument The instrument should only be used by individuals who are thoroughly skilled in high voltage laboratory techniques The following precaution should always be observed 1...

Страница 6: ...1 us Output power max 0 8 W Dual channel option Yes D option DC offset option1 50 Volts Connectors BNC Power 100 240 Volts 50 60 Hz Dimensions 100 mm x 430 mm x 375 mm 3 9 x 17 x 14 8 1 To specify the...

Страница 7: ...g Also check that your load is adequately shielded It may be necessary to enclose the load in a metal enclosure If any of the connectors on the instrument are unused they should be covered with shield...

Страница 8: ...ies to Directive 2002 96 EC categories 1 7 and 10 as stated in the Article 2 Scope section of Directive 2002 95 EC DIRECTIVE 2002 96 EC WEEE European customers who have purchased this equipment direct...

Страница 9: ...hree pronged recessed male socket is provided on the back panel for AC power connection to the instrument One end of the detachable power cord that is supplied with the instrument plugs into this sock...

Страница 10: ...ors are prevented access and or are insulated from every connection point In some cases connections must be exposed to potential human contact Operators must be trained to protect themselves from the...

Страница 11: ...ndoor use 2 altitude up to 2 000 m 3 temperature 5 C to 40 C 4 maximum relative humidity 80 for temperatures up to 31 C decreasing linearly to 50 relative humidity at 40 C 5 Mains supply voltage fluct...

Страница 12: ...the fuses on the rear panel are shown in the figure below AC FUSE REPLACEMENT To physically access the AC fuses the power cord must be detached from the rear panel of the instrument The fuse drawer ma...

Страница 13: ...g Case Size Recommended Replacement Part Littelfuse Part Number Digi Key Stock Number 1 2 AC 115 V 0 8A 250V Time Delay 5 20 mm 0218 800HXP F2418 ND 230 V 0 5A 250V Time Delay 5 20 mm 0218 500HXP F241...

Страница 14: ...onds If the overload condition has been removed the instrument will resume normal operation This overload indicator is only likely to come on in two situations Briefly at startup This is not a cause f...

Страница 15: ...o add a coaxial 50 Ohm terminator to this input to provide a proper transmission line termination The Pasternack www pasternack com PE6008 50 BNC feed thru 50 Ohm terminator is suggested for this purp...

Страница 16: ...detachable power cord that is supplied with the instrument plugs into this socket 2 AC FUSE DRAWER The two fuses that protect the AC input are located in this drawer Please see the FUSES section of t...

Страница 17: ...ffset The total output voltage amplified signal DC offset must remain within the range of 200 to 200V CABLE LENGTHS The length of cable used to connect the load to the output of the function generator...

Страница 18: ...orm The input impedance of the amplier is 1 k Connect a cable from the SYNC connector of the signal generator to the TRIG input of an oscilloscope Set the oscilloscope to trigger externally Connect th...

Страница 19: ...l generator 6 Rotate the gain control to its maximum setting The Channel 2 waveform should increase to 200V and have a shape similar to that of the Channel 1 waveform 7 Repeat the previous steps using...

Страница 20: ...factory for repair Service is to be performed solely by qualified service personnel Caution High voltages are present inside the instrument during normal operation Do not operate the instrument with t...

Страница 21: ...es may require replacement All fuses can be accessed from the rear panel See the FUSES section for details CLEANING If desired the interior of the instrument may be cleaned using compressed air to dis...

Страница 22: ...A C K A 4 W H I T E G 1 G R E E N G 2 G R N Y L W G 3 G R N Y L W C 1 R E D C 2 G R N C 3 P U R B B 1 R E D G 4 G R E E N 2 0 A W G A L P H A 3 0 7 3 U L S T Y L E 1 0 1 5 2 4 A W G B E L D E N 8 3 0...

Страница 23: ...G R E E N 2 0 A W G A L P H A 3 0 7 3 U L S T Y L E 1 0 1 5 2 4 A W G B E L D E N 8 3 0 0 3 M I L W 1 6 8 7 8 C 4 G R N C 4 G R N B M o l e x 1 9 0 7 3 0 0 1 3 r i n g t e r m i n a l 8 M o l e x 1 9...

Страница 24: ...8 1 2 3 4 5 6 J 3 6 4 0 4 4 5 6 1 5 V 1 5 V B U P O U T 1 1 5 V G N D 1 5 V p c b 1 5 8 N _ o v p p c b 1 5 8 N _ o v p s c h B U P O U T 1 1 5 V G N D 1 5 V 1 5 V B U E X T P O U T 2 N O U T N E G I...

Страница 25: ...9 4 7 u F 3 5 V C 6 2 2 u F L 2 4 3 4 1 3 1 0 1 M C 3 4 7 u F 3 5 V C 1 4 7 u F 3 5 V C 8 2 2 u F L 1 4 3 4 1 3 1 0 1 M C 4 4 7 u F 3 5 V C 1 2 2 2 u F L 4 4 3 4 1 3 1 0 1 M C 5 4 7 u F 3 5 V 1 2 3 4...

Страница 26: ...M O U N T A N Y 1 5 V N O N C M O S 5 5 5 1 4 1 2 Q 1 C M P Q 2 2 2 2 D I S A B L E O L O W H E N C H A R G I N G S H O R T S O U T B A S E W H E N C H A R G I N G B U 1 5 V G N D 1 5 V X 1 K E Y S T...

Страница 27: ...GN D 1 2 4V I N 2 M ON 3 EN 4 GN D 5 AD JUST 6 REF OUT 7 GN D 8 GN D 9 OU T 1 0 OU T 1 1 CASE 12 CASE 13 UV 1 1 8A 24 P20 D1 1N4750 C1 2 2uF CER CC W CW W TOP VIEW R7 5K 3266W R8 100 OY D3 1N4937 1 2...

Страница 28: ...0 A W G 2 4 A W G N E G O L O I N G N D O L O G N D 2 0 O R 2 4 A W G C A P B A N K G N D E X T P S I N I N O U T G N D G N D G R E E N G N D A M B E R S 1 A S 1 B D C S 2 A D C G N D C H S G N D S 2...

Страница 29: ...PERFORMANCE CHECK SHEET 29...

Отзывы: