Installation Instructions 

 

 

TYPES OF SYSTEMS 

 

 

 

This manual covers three of the basic types of systems offered by Avtec: 

• TAKU-Baffle Filter (AF) 
• Modular Grease Extractor (AX) 
• Auto Wash Down (AW) 

 

BAFFLE FILTER (AF) SERIES 

Model AF ventilators are listed by UL and are built in accordance of NFPA-96 for use 
with UL listed    re extinguishing systems  for duct hood protection. They are available 
with or without an automatic   re damper. They utilize UL classified removable baffle  
  filters to extract grease and provide a limited   re barrier. The canopy contains a hidden  
grease  trough  and  removable  cup.  Surface,  plenum  and  duct  collar      re  extinguishing 
systems may be factory supplied. 

 

MODULAR GREASE EXTRACTORS (AX) SERIES 

Model AX ventilators are listed by UL and are built in accordance of NFPA-96 for use 
with UL listed    re extinguishing systems  for duct hood protection. They are available 
with or without an automatic   re damper. These models utilize high velocity removable 
grease extractors. The canopy contains a hidden grease trough and removable cup. Sur- 
face, plenum and duct collar   re extinguishing systems may be factory supplied. 

AUTO WASH DOWN (AW) SERIES 

Model AW ventilators are listed by UL and are built in accordance of NFPA-96 for use 
with  UL  listed      re  extinguishing  systems  for  duct  hood  protection.  They  are  available 
with or without an automatic   re damper. These systems utilize a high velocity grease 
extractor and an integral  water  wash system cleans the inside of the grease extraction 
chamber either by  manual activation of the Wash Start button or by a programmable 
timer.    The duration of the  wash is electronically controlled. The  wash system is also 
activated by an electrical thermostat or a manual switch in the event of a   re condition. A 
surface   re extinguishing system is required and may be factory supplied.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

888-994-7636 

Содержание TAKU Premier Ventilation

Страница 1: ...mage to make a notation on the delivery receipt It will be the responsibility of the consignee to file a claim with the carrier We recommend that you do so at once Information contained in this docume...

Страница 2: ...1 Direct Draw Hoods page 11 Make Up Air Hoods page 11 Final Air Balance Make Up Air Hood back cover SAFETY PROCEDURES Do not attempt to service this unit yourself as removing covers may cause unnecess...

Страница 3: ...is manual for future reference NOTICE Due to a continuous program of product improvement Avtec reserves the right to make changes in design and specifications without prior notice NOTICE Please read t...

Страница 4: ...ng systems for duct hood protection They are available with or without an automatic re damper These models utilize high velocity removable grease extractors The canopy contains a hidden grease trough...

Страница 5: ...ation and very carefully uncrate hood 3 Raise hood to proper hanging height 4 Suspend hood from adequate roof supports using 1 2 threaded rods with nuts and washers See Fig 1 5 Level hood left to righ...

Страница 6: ...and airline cable on exhaust fan cap and metal curb Remember to leave ample room for fan to tilt back Fan will remain in tilted back position 7 Install grease collection box on side of fan that has g...

Страница 7: ...designed to control the operation of the ventilator exhaust and make up air fans and wash the grease extraction plenum with hot water detergent solution The fan operation and wash sequence can be sta...

Страница 8: ...vided HING 40 MINIMUM EXHAUST DUCTALL WELD CONSTRUCTION CEILING See Fig 6 1 Side skirts are offset at the top and have a 90 bend inward at the rear 2 Skirts are to overlap the outside of the hood Bolt...

Страница 9: ...e panels are to be installed Retaining nuts and washers are installed on the studs prior to shipping 2 Loosen nuts on studs Slide enclosure panel under loosened nuts Holes in panels are open on end so...

Страница 10: ...er panel by sliding tabs into slotted holes in upper panel screw bottom flange to wall 4 Caulk horizontal seam with NSF approved silicone sealant 5 When hood is hung it will rest on top panel NOTE Be...

Страница 11: ...moving toward the dining area 9 Repeat steps 6 and 7 until all vapors are captured 10 Same as step 7 with bottom of next page NOTE The exhaust and supply if any air flow rates were established under...

Страница 12: ...t to operating temperature 4 Produce large quantities of smoke or steam 5 Observe capture of vapors 6 If all vapors are not totally captured ne tune the system by adjusting the air volume control damp...

Отзывы: