INTRODUCTION 

The 

MAGIC ACip3

 is a pure IP Audio Code and provides three Ethernet interfaces 

which can be used for Audio over IP transmissions, to control the system with the 

Windows PC software or to integrate it into a network management system via 

SNMP. Alternatively, 

MAGIC ACip3 2M

 provides an E1 interface in order to 

implement the classic feed via 2 Mbit networks. 

The Audio programmes can – flexibly and freely assignable – be fed in or given out, 

respectively, via an analogue and two digital stereo interfaces (1 x Stereo analogue 

XLR, 2 x Stereo digital AES SUB-D 15-pin). Furthermore, both systems provide a 

headphones interface for audio monitoring. For external signalling and switching 

commands six programmable TTL interfaces and six relays are available. 

The systems support the G.711, G.722, ISO/MPEG Layer 2, Opus coding algorithms 

and PCM 16/20/24 Bit in the standard delivery version. Optionally, the Audio 

Codecs can be upgraded with Enhanced apt-X 16/24 Bit, AAC-LD/AAC-ELD and AAC-

LC+V1/V2. 

MAGIC ACip3 and MAGIC ACip3 2M are designed as 19” system with integrated 

wide area power supply and provide optionally an external 

redundant power 

supply

. The systems feature a signal processor-based hardware platform without 

fan. 

Via LAN, two operating modes are available: the system can be used for dial-up 

AoIP connections according to the EBU Tech 3326 standard or IP Leased Line 

connections. In AoIP mode, the system can register at 5 different SIP servers and 

automatically accept incoming calls from this SIP server. Audio connections in IP 

Leased Line and in AoIP dial-up Mode can be established with the 

Secure Streaming 

functionality for a highly reliable transmission. With this feature, a connection can 

be established via two independent IP links to ensure highest reliability. It is 

possible to use either one or two Ethernet interfaces for this functionality. 

In case that no connection at all can be established, it is also possible to play an 

emergency programme from an 

SD card

. With the Backup Upgrade a main and a 

backup connection can be configured.  

The systems encode one stereo programme in the standard version and can 

optionally be upgraded to 

a second stereo programme

 by software activation (2-

Channels Upgrade Package).  

The Audio Codecs can be operated via the front panel or even more comfortably via 

the Windows PC Software supplied with the delivery. 

Via the 

Ember+

 protocol 64 inputs and 64 outputs can be programmed, an easy 

communication between Audio Codec and e.g. DHD or LAWO mixing consoles is 
possible. 

With the optional 

Distribution Upgrade

 MAGIC ACip3 can be used as Audio 

contribution codec for Studio-Transmitter-Links. 10, 20 or up to 50 participants can 

dial into a central codec via SIP. In the integrated access protection list up to 50 

participants can be entered. 

 
 
 

 

Содержание MAGIC ACip3

Страница 1: ...MAGIC ACip3 MAGIC ACip3 2M High quality IP and E1 Audio Codec Hardware Manual ...

Страница 2: ...park 91 90411 Nuernberg Germany Phone 49 911 5271 0 Telefax 49 911 5271 100 AVT Audio Video Technologies GmbH All Rights reserved Reproduction in whole or in parts is prohibited without the written consent of AVT GmbH Subject to changes Release date January 2019 ...

Страница 3: ...interfaces 14 3 2 E1 interface only MAGIC ACip3 2M 14 3 3 TTL Relay interface 15 3 4 RS232 interfaces 16 3 5 Audio interfaces 17 3 5 1 Headphone interface 17 3 5 2 Analogue Audio interfaces 17 3 5 3 Digital AES Audio interfaces 18 3 6 Power supply 19 3 6 1 AC power supply interface 19 3 6 2 Additional DC power supply connection 19 3 7 SD Card Slot 19 4 Technical Data 20 5 General 23 5 1 Order numb...

Страница 4: ...r dial up AoIP connections according to the EBU Tech 3326 standard or IP Leased Line connections In AoIP mode the system can register at 5 different SIP servers and automatically accept incoming calls from this SIP server Audio connections in IP Leased Line and in AoIP dial up Mode can be established with the Secure Streaming functionality for a highly reliable transmission With this feature a con...

Страница 5: ... possible 1 2 Safety The unit described has been designed to the latest technical parameters and complies with all current national and international safety requirements It operates on a high level of reliability because of long term experience in de velopment and constant and strict quality control in our company This manual contains basic safety instructions that must be observed during configur...

Страница 6: ...he device must be protected from water The device may only be installed in indoor rooms The device may only be cleaned with a dry cloth Any conversions or alterations to the unit or to parts of the unit including software must be carried out by trained personnel authorised by the ma nufacturer Any conversions or alterations carried out by other persons lead to a complete exemption of liability Onl...

Страница 7: ...s and connections A headphone interface is also on the front The other interfaces of the system 3 LAN interfaces Audio interfaces RS232 and GPIO interfaces as well as power supply connections SD card slot and for the 2M version E1 interface are on the rear side MAGIC ACip3 Front View MAGIC ACip3 Rear View MAGIC ACip3 2M Front View MAGIC ACip3 2M Rear View ...

Страница 8: ...ignal processors In this way the following functions are realized DSP1 G 711 Codec G 722 Codec ISO MPEG Layer 2 Layer 3 MPEG 4 AAC LD AAC ELD HE AAC LC V1 und V2 Opus Control of the complete system Keypad display relays TTL RS232 DSP2 apt X Codec DSP3 Second apt X Codec The configuration and operation can be carried out via the front keypad and the illuminated display Configuration and control are...

Страница 9: ... sure that there is sufficient ventilation it is recommended to keep a spacing of ca 3 cm from the openings In general the ambient temperature of the system should be within the range of 5 C and 45 C These thresholds are specially to observe if the system is inserted in a rack The system works without ventilation The system temperature can be indicated on the display under MENU STATUS INFORMATION ...

Страница 10: ... power cable MAGIC ACip3 may only be operated with one of the included power supplies listed below Sunny Model SYS1541 2412 100 240 Vac max 1 0 A 50 60 Hz 12 Vdc 2 0 A EN60950 LPS Sunny Model SYS1357 2412 100 240 Vac max 1 0 A 50 60 Hz 12 Vdc 2 0 A EN60950 LPS After plugging the power cable and switching on the device the unit boots in a few seconds A 12 V DC voltage can be supplied to the 12 V so...

Страница 11: ...red flashing Provides a common signal based on the status of INFO 1 and INFO 2 Permanent green One codec connection INFO1 or INFO2 lights green Permanent green Two codecs connections INFO1 and INFO2 lights green Flashes red One codec connection INFO1 or INFO2 flashes red Flashes red Two Codecs connections INFO1 or INFO2 or both flash red ALARM red or red flashing Permanent red in case of System al...

Страница 12: ...revent potential damage to the environment and health The device contains valuable raw materials that can be reused Therefore return the appliance to an appropriate collection point Detailed information on the disposal of your old appliances can be obtained from your local authority your waste disposal service the specialist dealer where you purchased the product or your sales contact These statem...

Страница 13: ...ront The other interfaces of the system 3 LAN interfaces Audio interfaces RS232 and GPIO interfaces as well as power supply connections SD card slot are on the rear side MAGIC ACip3 Front View MAGIC ACip3 Rear View MAGIC ACip3 2M provides an additional E1 interface at the rear side MAGIC ACip3 2M Front View MAGIC ACip3 2M Rear View ...

Страница 14: ...uto neg 10 100 Mbit s Recommended cable CAT5 or higher Max cable length 100m 2 TX Data out 3 RX Data in 4 not used 5 not used 6 RX Data in 7 not used 8 not used 3 2 E1 interface only MAGIC ACip3 2M A symmetrical E1 interface is optionally available for classic audio feed via 2 Mbit networks The pin assignment is shown below Pin assignment E1 Interface Socket RJ 45 Pin Signal Electrical characteris...

Страница 15: ...um current 10 mA Relay interface Maximum voltage 48 V Maximum current 200 mA 2 TTL 1 input output 3 TTL 2 input output 4 TTL 3 input output 5 RELAY 1 COMMON 6 RELAY 2 NC 7 RELAY 2 NO 8 RELAY 3 COMMON 9 RELAY 4 NC 10 RELAY 4 NO 11 RELAY 5 COMMON 12 RELAY 6 NC 13 RELAY 6 NO 14 TTL 4 input output 15 TTL 5 input output 16 TTL 6 input output 17 RELAY 1 NC 18 RELAY 1 NO 19 RELAY 2 COMMON 20 RELAY 3 NC 2...

Страница 16: ...ocket SUB D 9 pin Pin Signal Electrical characteristics 1 not used Level V 24 RS232 Data rate max 115200 Baud Scope max 15 m RS232 Protocol 1 Start bit 8 Data bits 1 2 Stop bit Parity adjustable 2 TXD RS232 Data a 3 RXD RS232 Data b 4 not used 5 GND 6 not used 7 not used 8 not used 9 not used a ATTENTION on this pin the MAGIC ACip3 sends data b ATTENTION on this pin the MAGIC ACip3 receives data ...

Страница 17: ...ogue stereo input and output Audio 1 Audio 2 Two XLR sockets are available for the input and two XLR plugs for the output The pin configuration of socket and plug are displayed below Pin assignment Analogue Audio input Socket 3 pin XLR Pin Signal Electrical characteristics 1 GND Ground 2 A 3 B Pin assignment Analogue Audio output Socket 3 pin XLR Pin Signal Electrical characteristics 1 GND Ground ...

Страница 18: ...tains the digital AES interfaces The pin configuration of the 15 pin SUB D socket can be seen below Pin assignment Digital Audio interface AES Socket SUB D 15 pin Pin Signal Electrical characteristics 1 AES 1 IN IEC 958 2 AES 1 IN 3 AES 2 IN 4 AES 2 IN 5 AES 1 OUT 6 AES 1 OUT 7 AES 2 OUT 8 AES 2 OUT 9 GND 10 CLOCK IN OUT 11 15 GND ...

Страница 19: ... connection A DC voltage of 12V can be fed to the additional power supply input Pin assignment Additional power supply Socket KYCON KPJ S3 Pin Signal Electrical characteristics 1 GND Voltage 12V Power max 30W 2 12V 3 not used 3 7 SD Card Slot A slot for a standard SD SDHC card with max 32 GByte is available at the back of the system ...

Страница 20: ...ISO MPEG Layer 2 Opus Optional ISO MPEG Layer 3 MPEG4 AAC LD ELD MPEG4 AAC LC MPEG4 HE AACv1 v2 Enhanced apt X 16 24 Bit Line interfaces 3 x Ethernet 10 100 Mbit s 1 x E1 only MAGIC ACip3 2M Control interfaces 3 x Ethernet 10 100 Mbit s 6 x Relays 6 x TTL Input Output ...

Страница 21: ...response G 711 50 Hz 3400 Hz G 722 50 Hz 7000 Hz MPEG 20 Hz 20000 Hz depending on bitrate 2 x Stereo Digital Audio IN OUT o Format IEC 958 AES o Balanced inputs and outputs o Connection 15 pin SUB D socket o Impedance 110 W 1 x Headphones o 6 3 mm Stereo jack Data interfaces 2 x RS232 Sampling rates 8 16 24 32 48 kHz depending on coding algorithm Data rates net 8 2304 kBit s depending on coding al...

Страница 22: ...ed power supply AC 100 V 230 V Power max 30 W Redundant external power supply opt DC 12 V Power max 30 W Power input Typ 15 W max 30 W Dimensions W x H x D 434 mm x 44 5 mm x 260 mm Weight Ca 3 7 kg Further Information Temperature Range 5 C 40 C Relative humidity 30 85 Mains voltage 100V 230V Mains frequency 50Hz 60Hz Power consumption max 30W ...

Страница 23: ...LD Codec Upgrade 450306 MPEG4 Upgrade 450314 2 Codecs Upgrade Package 803222 12V external power supply 470080 AES EBU CLK Adapter Cable 490171 5 2 Scope of delivery MAGIC ACip3 MAGIC ACip3 2M Audio Codec o 1 x power cable o 4 x Self adhesive feet o 19 Mounting brackets integrated in front panel 5 3 Declaration of conformity The declaration of conformity you will find at the end of this manual ...

Страница 24: ...ly please note down the factory number of the unit as well as the software version that you use The factory number is visible in the software under Administration Registration If you bought the system via your local dealer please contact him first 6 3 Repairs If contrary to expectations your unit is defective please fill in the attached Service Request1 and send the unit to the following address A...

Страница 25: ...tro und Elektronikgeräten RoHS Restriction of the use of certain hazardous substances in electrical and electronic equipment RoHS 2011 65 EU incl Directive EU 2015 863 DieÜbereinstimmungwirdnachgewiesendurchvollständigeEinhaltungfolgenderNormen Theconformityisevidencedbystrictlymeetingthefollowingstandards EN61010 1 EN61000 3 3 EN61000 4 5 EN50581 EN61000 3 2 EN61000 4 6 EN55022 EN61000 4 2 EN6100...

Отзывы: