- 4 -
IST1073V1.0
RECEIVER RVS
Installation Manual
General information
•
Only one RVS receiver can be associated with the Raptor series control panel (not compatible with Raptor LC). It is able to receive the Video if
combined with wireless detectors with CAM included and to manage the firmware upgrade.
•
RVS does not manage remote controls, wireless sirens and wireless keypads, which are received and managed directly by the control panel.
• RVS
manages footage from
up to 125 sensors
.
• RVS
should be plugged into a dedicated connector in the control panel main board.
•
Non-volatile events memory able to save up to 125 video
•
It has two wireless sections: one for standard wireless communications, the other for receiving images. Both operate at 868 MHz but, while
standard communications travel at 9600bps, images at 100 Kbps to minimize transfer time
•
Before installation, it is recommended to check the effective range of each sensor. Remember that the image transmission may have a lower
wireless range than standard communications.
•
Each movie consists of 10 frames, one every 0.5 seconds: the first 5 are before to the alarm and the last 5 after the alarm.
•
The size of a movie is typically between 60 and 100 Kbytes, depending on the images, to which 20Kbytes are added, if audio is enabled.
•
To optimize energy savings, the device manages, in real time, information on the status of the control panel (OFF or ON, HO, etc ...) and of the
sensors included in the arming (ON, HO, etc ...). The shooting and transmission of the videos will be activate only if the detectors are “armed”.
Furthermore, if 2 or 3 detectors would be in alarm at the same time, manages the radio transfer of the videos making sure that the transmissions
line up orderly to avoid interference.
General characteristics
Capacity in open field
~ 200 meters
Programming:
from keyboard with guided menu or by software
Video management
of wireless detectors with cam
Audio management
of wireless detectors with audio
Memory
non-volatile events memory able to save up to 125 video
Connections:
Dedicated plug-in connector in the main board
Board Dimensions: (L x H x P):
43 x 19 x 10 mm
Container: (L x H x P)
+5 °C / +55 °C
Voltage:
nominale di alimentazione: 13,8 V =
Current consumption:
At rest: 10 mA / Receiving: 15 mA / Transmission: 30 mA
Protection grade:
IPX0
Environmental Class
Classe II
EN 50131- 1, EN 50131- 3, EN 50131-5-3
N° Certificazione INCERT
XXXXXXXXXXXXXX
Bande di frequenza usate
Occupied frequency bands
(ETSI EN 300 220-3-2 V1.1.1 (2017-02)
Wireless alarm equipment)
Massima
potenza irradiata
Maximum
radiated power
Numero di banda
Band number
According to EC Decision
2013/752/EU [i.2]
Numero di sottoclasse
della Classe 1
Class 1 sub-class number
Commision Decision 2000/299/EU [i.5]
A
868,600 MHz to 868,700 MHz
<10 mW e.r.p.
49
32
D
869,300 MHz to 869,400 MHz
<10 mW e.r.p.
53
72
E
869,650 MHz to 869,700 MHz
<10 mW e.r.p.
55
34
Banda di frequenza per trasmissione immagini
Occupied frequency band for image trasmission
(ETSI EN 300 220-3-2 V3.1.1 (2017-02)
Non-specific short range devices)
Massima
potenza irradiata
Maximum
radiated power
Numero di banda
Band number
According to EC Decision
2013/752/EU [i.3]
Numero di sottoclasse
della Classe 1
Class 1 sub-class number
Commision Decision 2000/299/EU [i.7]
868,700 MHz to 869,200 MHz
<10 mW e.r.p.
50
29
RVS receiver and wireless video detectors Firmware update
• RVS update
: performed through XWIN by connecting the PC to the control panel via the USB port and activating the “USB connection” from the
keypad. Once the customer has been opened in XWIN, select the path “
Service
>
Firmware Update
>
RVS
” and select the RVS firmware file
•
Wireless Video detectors Firmware update
: the same procedure is carried out for the RVS receiver, but selecting the detector firmware.
Once the file has been downloaded to the control panel, the RVS receiver creates a detector list, among those acquired, which need to be updated.
Using the Keypad, enter programming, select the path “
Wireless Device Management
>
Agg.Fw.Sens.RVS
” and press “
ENT
”.
The message “
Waiting for connection
” appears on the keypad display, as soon as a detector communicates with the control panel, the firmware
update begins and it is signaled with the message “
in progress
...” on the control panel display and the flashing of detector led.
The procedure will end only when all detectors have been updated.
•
Deleting Wireless Video detectors firmware, stored in the RVS Receiver
: using the keypad, enter programming, select the path “
Wireless
Device Manager
>
RST.fw.sens.RVS
” and press “
ENT
”.
WARNING
: TO AVOID IRREVERSIBLE MALFUNCTIONS, DO NOT DISCONNECT THE POWER SUPPLY OR RESET THE DEVICES DURING
THE UPDATE PROCEDURE.
INSTALLATION AND MAINTENANCE MUST BE PERFORMED BY QUALIFIED PERSONNEL
The product complies with the European Directives for CE marking.
E
N
G