connect/Control
Connect: Network/Lan
•Click on box above NETWORK/LAN
•Default IP = 192.168.001.239o (Changing the IP address requires using the web interface or
sending direct control commands via an RS-232 Connection and Terminal app.
#baud rate 57,600)
•Click the “CONNECT TO FRESCO” button underneath NETWORK/LAN settings
Connect: USB/RS-232
•Click on the box above USB/RS-232.
•For USB/RS-232, you can opt the connect via the ISP/CONTROL Mini USB port on the front of the
FRESCO, or alternately use the 3-pin Phoenix CONTROL connection on the back.
•For USB/RS-232, click the “SEARCH FOR VIDEO WALL PROCESSOR” button (Magnifying Glass). The
FRESCO COMM PORT#, DEVICE ID, and NAME will automatically fill the data fields
•If the FRESCO is found, click the “CONNECT TO FRESCO” button underneath the USB/RS-232
settings
Measure
•Enter the MANUFACTURER
and MODEL info.
•Use ONLY Millimeters to take
measurements (due to their added
precision).
•Take measurements of the VISIBLE
WIDTH, HEIGHT and thicknesses of ALL
FOUR BEZELS (TOP, BOTTOM,LEFT, RIGHT).
•Click the “SAVE DISPLAY INFORMATION”
button (This info will be saved for future use).
•Click the “OPEN DISPLAY INFORMATION” button to load previously saved display info. (IF NEEDED)
•NOTE: If all of your displays are the same make and model, next CHECK the 3 “COPY DISPLAY
1” boxes. The display info from the DISPLAY-1 box will be auto entered into the other three
display rectangles
Select the “OUTPUT RESOLUTION” from the drop-down menu.
•OUTPUT RESOLUTION options: 720P, 1080P, 4K 30HZ 4:4:4, 4K 60HZ 4:2:0, and 4K 60HZ 4:4:4
Generate video wall
Click on “
Generate Video Wall
”. For a more in depth calibration click on advanced set-
tings. You can also set the output resolution to desired setting.