The camera can be controlled via RS-485, Half-duplex mode. The parameters are:
• Baud rate: 2400/4800/9600
• Start bit: 1 bit
• Data bit: 8 bits.
• Stop bit: 1 bit.
• Parity bit: none.
IP (Network) Connection
Execute the following steps to connect the controller and an Avonic PoE camera to a LAN:
Connect the controller and the camera to a (PoE) switch. Use for this an Ethernet connection. See
. See also the diagram below:
In case more cameras are connected to the controller, each camera needs to be addressed the right
way to a camera number of the controller. The following settings need to match in both camera and
controller:
1.
Protocol (VISCA, PELCO-p or PELCO-d)
2.
Camera address number (1, 2 or n)
3.
Communication settings as baud rate (9600), parity, etc.
Figure 5: IP Network Connection Diagram
RS-232 (VISCA) Network Connection
Execute the following steps to connect the controller to the back of the camera(s) via RS-232:
1.
Make the connection using
daisy chaining
network architecture.
2.
Keep in mind that the maximum cable length for RS-232 is 10-15m.
Figure 6: RS-232 Network Connection Diagram
User Manual AV-CON300-IP
| www.avonic.com
16