Product Overview

Feature Overview

The SwitchView allows you to control multiple PCs, 

easily and affordably, with just one keyboard, monitor 

and mouse. There is no software to install or boards 

to configure, so installation is simple. SwitchView works 

with IBM PC/AT and PS/2 systems with support for 

VGA and SVGA video. PS/2 keyboard and PS/2 mouse 

peripherals are supported through the rear of the unit.

When you turn on your PCs, the SwitchView will boot 

up each one without interruption by sending out the 

proper signal to eliminate keyboard errors. PCs may be 

powered-up one-at-a-time or all at once. The first avail-

able channel is automatically selected upon power-up. 

You can switch computer channels two ways: via the 

Select button on the SwitchView front panel, or through a 

short keyboard sequence if the SwitchView is out of reach.

The SwitchView supports the following additional features:

 • 

PS/2 mouse translation

 - your PS/2 mouse will 

work with any attached PC, regardless of whether 

the computer is serial or PS/2 mouse compatible! 

 

    Extensive Mouse Support - 

The SwitchView 

offers full support for the Logitech MouseMan 

Wheel, Logitech Trackman Marble Wheel, Logitech 

Trackman Marble FX, Microsoft Explorer mouse and 

the Microsoft IntelliMouse family.

 

• 

Standard cables

 - use either Avocent-supplied or 

standard straight-through cables to attach comput-

ers to the SwitchView unit.

 

• 

Built-in scanning feature

 - scan through all of 

your attached PCs automatically. Scan every PC for 

2 to 60 seconds each.

1

Содержание SwitchView

Страница 1: ...SwitchView Installer User Guide Technology Corporation Expert Solutions for the LAN Environment ...

Страница 2: ... reserved Avocent and the Avocent logo are trademarks or registered trademarks of Avocent Corporation SwitchView is a registered trademark of Cybex Computer Products Corporation All other marks are the property of their respective owners ...

Страница 3: ...selected upon power up You can switch computer channels two ways via the Select button on the SwitchView front panel or through a short keyboard sequence if the SwitchView is out of reach The SwitchView supports the following additional features PS 2 mouse translation your PS 2 mouse will work with any attached PC regardless of whether the computer is serial or PS 2 mouse compatible Extensive Mous...

Страница 4: ... Temperature 41 5 C to 104 40 C Storage Temperature 4 20 C to 122 50 C Optional Power Supply 6VDC 700 mA Supported Hardware Computer IBM PC AT PS 2 and 100 compatibles Video Modes VGA and SVGA Maximum Resolution 1600 x 1200 75 Hz Peripherals PS 2 keyboard PS 2 mouse Regulatory Compliance Standards UL 1950 CSA C22 2 No 950 EN60950 FCC part 15B EN55022 EN50082 CISPR22 ICES 003 Under certain circumst...

Страница 5: ...S 2 PSs CPS2 6A For AT serial PCs CSER 6A The SwitchView also accepts standard straight through cables for these connections Connecting your peripherals 1 Your VGA monitor keyboard and mouse connect to the SwitchView unit instead of your computer Plug your PS 2 keyboard cable into the purple port on the back of your unit in the User Console section Plug your PS 2 mouse cable into the green port an...

Страница 6: ... of any available port on your SwitchView Ports are labeled A B on the 2 Port and A D on the 4 Port Next plug your mouse cable into the green con nector of the same port Plug the video cable into the blue monitor connector Plug the remaining cable ends into the matching ports on your computer For serial computers use only Avocent provided adaptors Tighten all thumbscrews 4 Repeat step 3 for each a...

Страница 7: ... is by entering a short sequence of keystrokes on the keyboard This is called keyboard or hot key switching Press the Control key twice within one second to place your SwitchView in Command Mode Your keyboard LEDs will flash to verify that you are operating in Com mand Mode Now whatever you type will be interpreted as SwitchView system commands until Enter is pressed to accept the command or Escap...

Страница 8: ...d scanning see the commands below Key Sequence Action CTRL CTRL Dnn Enter Configures the dwell time Substitute nn with a value from 2 to 60 seconds The default value is 5 seconds CTRL CTRL SG Enter Enables the scan Go command CTRL CTRL SH Enter Enables the scan Halt command Key Sequence Action CTRL CTRL M Enter Mouse will suspend scanning CTRL CTRL M Enter Mouse will not suspend scanning default E...

Страница 9: ... unit Unable to hot key After a power loss the unit will default to the CTRL CTRL key sequence Try using CTRL CTRL to hot key switch Video No video Verify that the video cable between the computer and the SwitchView is connected to the selected port Verify that the monitor cable is correctly connected to the SwitchView Power down the computer Connect the monitor directly to the computer and power ...

Страница 10: ... If your mouse type is not listed use the MR keyboard sequence Verify that the mouse is plugged into the mouse port in the User Console area on the rear panel of the unit Verify that the computer works properly with a mouse connected directly to it If not try another mouse If you are using a serial mouse verify that you are using an Avocent Serial Mouse adaptor 8 Peripheral Mouse Logitech MouseWar...

Страница 11: ...rks properly connected directly to the computer If not try a different keyboard If the keyboard still does not function cycle power on all attached computers and try again Keyboard is inoperable after switching channels or characters on screen do not match keyboard input Try changing the keyboard scan set by using the key board command sequence CTRL CTRL Kn Enter where n is a scan set number 1 3 I...

Страница 12: ...l if you re using a PC with a Microsoft Intel liMouse driver See page 8 CTRL CTRL Kn Enter Sets keyboard scan set n is a number 1 3 CTRL CTRL AV Enter Displays the current firmware version of the SwitchView processors You must be at a DOS prompt or in a text editor word processor to view this information CTRL CTRL H1 Enter Default Command Mode Activation CTRL CTRL H2 Enter Changes the Command mode...

Страница 13: ...o or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Cons...

Страница 14: ......

Страница 15: ...emission standards and each cable is individually tested under load 2 If defect or malfunction was caused by abuse mishandling unauthorized repair or use other than intended 3 If unauthorized modifications were made to product 4 If unreported damages occurred in any shipment of the product 5 If damages were due to or caused by equipment or software not provided by Avocent 6 If the SwitchView is us...

Страница 16: ...0 Fax 49 89 599 08350 E mail techsupp_eur avocent ie Avocent Asia Pacific 100 Tras Street 15 01 Amara Corporate Tower Singapore 079027 Tel 65 227 3773 Fax 65 223 9155 E mail info asiapac avocent com Avocent Canada 20 Mural Street Unit 5 Richmond Hill Ontario L4B 1K3 Canada Tel 1 877 992 9239 Fax 1 877 524 2985 E mail mail avocentcanada com 590 115 001 REV B Technology Corporation Expert Solutions ...

Отзывы: