This document outlines: 
1. Update Instructions 
2. Appliance Firmware Version and Language Support Information 
3. Enhancements 
4. Fixes 
5. Known Issues 
6. Change Log 
 
 
================================================================================== 

Update Instructions 

================================================================================== 
 
Please refer to your Installation, Administrator and User manual for detailed instructions to update the 
Cyclades OnSite appliance to version 3.1.0. 
 
 
================================================================================== 

Appliance Firmware Version and Language Support Information 

================================================================================== 

 
Appliance/Product

 

Firmware Type

 

Version

 

Filename

 

Cyclades OnSite 

Opcode 

V_3.1.0 

fl0541002.bin 

 
 
================================================================================== 

Enhancements 

================================================================================== 
 
This release contains the following enhancements: 

 
I. 

Integration of Cyclades OnSite Appliance into DSView 3 Management Software 

The Cyclades OnSite appliance is integrated into DSView 3 software using Cyclades OnSite Plug-in 
Version 1.2.0. This allows access, configuration and management of Cyclades OnSite appliance from 
DSView 3 management software. It is required to have Cyclades OnSite firmware version 3.1.0 and 
Cyclades OnSite Plug-in version 1.2.0 for DSView 3 software version 3.4 or later to manage Cyclades 
OnSite appliances. 
 
Please refer to your DSView 3 software version 3.4 and Cyclades OnSite Plug-in version 1.2.0 manual and 
release notes for detailed configuration instructions. 
 

II.  Support for Centralized Authentication 

Support for Centralized Authentication through DSView 3 software has been added. This is in addition to the 
existing authentication types supported in Cyclades OnSite console server. The three new authentication 
types added into Cyclades OnSite appliance are DSView, DSView/Local or DSViewDownLocal. To enable 
centralized authentication, any of the three DSView 3 authentication types should be selected. When one of 
these three (3) authentication type is selected, the Authentication Service configured in DSView 3 software 
is used to authenticate users accessing the Cyclades OnSite appliance. DSView/Local is selected by default 
for centralized authentication. 

 
III.  Support for Centralized Data Logging 

Support for Centralized Data logging through DSView 3 software has been added. This is in addition to the 
data logging functionality in Cyclades OnSite console server. Only one of the data logging types can be 

Содержание Cyclades OnSite Branch Office Appliances

Страница 1: ...e Plug in version 1 2 0 for DSView 3 software version 3 4 or later to manage Cyclades OnSite appliances Please refer to your DSView 3 software version 3 4 and Cyclades OnSite Plug in version 1 2 0 manual and release notes for detailed configuration instructions II Support for Centralized Authentication Support for Centralized Authentication through DSView 3 software has been added This is in addit...

Страница 2: ...gement software interface 2 IPDU auto detection a Once an IPDU is plugged in one of the serial ports configured as power management its speed type model and name can be automatically detected b If auto detection is not enabled the user will have to specify the IPDU type and speed c With the IPDU auto detection feature adding and dropping IPDUs in a daisy chain can be dynamic eliminating the re con...

Страница 3: ...Sun and any time of the day for Day Light Savings c With the passing of Energy Policy Act of 2005 by the United States Congress which is effective since March 2007 this feature will allow easy configuration of such changes in Day Light Savings laws X Linefeed suppression extended to SSH a Linefeed suppression option was extended to SSH sessions b Configuration is the same as for Telnet sessions wh...

Страница 4: ...r APM v1 4 1 3 When the upgrade operation is performed from DSView 3 software make sure to review the Operation Results It is also recommended that the DSView 3 status polling is disabled when firmware upgrade is run NOTE DO NOT re boot the unit if OnSite firmware upgrade fails It may result into flash corruption 4 Changing the authentication type to from NIS will require the restart of the follow...

Страница 5: ...in telnetd L bin login 7 The etc sudoers file was changed to include commands for DSView 3 software Integration 8 CLI and Web interfaces were modified to support configuration changes in the redesigned Power Management daemon 9 CLI and Web interfaces were modified to support configuration changes in the redesigned Power Management daemon 10 PM Firmware upgrade command pmfwupgrade syntax changed pm...