18
PA8, setting of phono card
To ensure that the phono card works in an optimal way, it must be set according to the requirements of the
cartridge. Please refer to the operating manual / technical data of your cartridge to find out the correct
settings. The setting is done by switches on the pcb. The upper switches are for the left channel, the lower
for the right channel. The switches for both channels must be set identically. You can set: sensitivity,
cartridge (MM or MC) and cartridge load. For fine tuning of sensitivitiy see additionally the level function of
the PA8 (see 3.4.1 Setting of input sensitivity).
S1/1 S1/2 S2/1 S2/2 S3/1 S3/2
S4
1+2
S5/1 S5/2
MM-cartridges
OFF OFF OFF
Output voltage
< 1 mV
OFF OFF
1 mV – 2,5 mV
ON OFF
2,5 mV - 5 mV
OFF ON
> 5 mV
ON
ON
Load capacitance
up to 200 pF
OFF OFF OFF OFF
200 - 350 pF
OFF OFF ON OFF
350 - 450 pF
OFF OFF OFF ON
450 - 600 pF
OFF OFF ON
ON
S1/1 S1/2 S2/1 S2/2 S3/1 S3/2
S4
1+2
S5/1 S5/2
MC-cartridges
ON
ON
ON
Output voltage
< 100
µ
V
OFF OFF
100
µ
V - 250
µ
V
ON OFF
250
µ
V - 500
µ
V
OFF ON
> 500
µ
V
ON
ON
Load resistance
25 - 75 Ohm
ON
ON OFF OFF
75 - 150 Ohm
ON OFF OFF OFF
150 - 500 Ohm
OFF ON OFF OFF
> 500 Ohm
OFF OFF OFF OFF
Please refer also to manual PA8 "
2.4.1 Automatic software update"