background image

Head Office

+61 (0)3 5977 6128

Avlite USA

+1 (603) 737 1311

Avlite Asia

+65 9119 8770

General Enquiries

[email protected]

Step 2: Adjustment of LED Floodlight Unit

AV-HL-FL-PV models: Determine to which group each 

individual light belongs. 

Set the light group by adjusting the Rotary Switch A on 

the PCB to the appropriate light group (E.g. 0, 1, 2 etc).

AV-HL-FL-DC or UM Models: Wire the LED Floodlight 

Unit into the daisy chain configuration via the junction 

box. Follow the wiring instructions in section 7.0 of the 

Installation Manual.

Step 3: Set the Light Group (PV Model Only) 

or wire the Floodlight unit (DC and UM Mod

-

els Only)

AV-HL-FL-PV models: Determine to which group each 

individual light belongs. 

Set the light group by adjusting the Rotary Switch A on 

the PCB to the appropriate light group (E.g. 0, 1, 2 etc).

AV-HL-FL-DC or UM Models: Wire the LED Floodlight 

Unit into the daisy chain configuration via the junction 

box. Follow the wiring instructions in section 7.0 of the 

Installation Manual.

Step 4: Test and secure

AV-HL-FL-PV models: Test the operation of the light by 

using the Radio Controller

Close the PCB enclosure and Solar Assembly. Secure the 

lid with the provided bolt.

AV-HL-FL-DC and UM Models: Test the Operation of the 

lighting circuits in the Helipad Lighting System using 

the Primary Helipad Controller (AV-HL-CTRL-T1 or AV-

HL-CTRL-T2)

Bolt the light to its final location.

Junction Box (UM or DC)

Note: 

Power and Data cables 

can be wired into the junction 

box from the left or right hand 

side

Junction Box (UM or DC)

Note: 

Power and Data cables 

can be wired into the junction 

box from the left or right hand 

side

 Internal wiring to Light 

Head Assembly

Junction Box (UM or DC)

Note: 

Power and Data cables 

can be wired into the junction 

box from the left or right hand 

side

 Internal wiring to Light 

Head Assembly

PV Model

DC and UM Models

Alwa

y

s On

 

Dusk till Dawn