Route top junction box to control unit cables
Wiring instructions-Data Cable:
•
Connect the white Alarm Common (COM) conductor from the top-level junction box
to the ‘MI Alarm Common’ labelled terminal on terminal block 1 in the Control Unit
•
Connect the black alarm signal (NC) conductor from the top-level junction box to the
‘MI Alarm Signal’ labelled terminal on terminal block 1 in the Control Unit
•
Connect the green Photocell Output (PC) conductor from the top-level junction box
to the ‘MI PC Input’ labelled terminal on terminal block 1 in the Control Unit