3.  Install the L-810 Dual Light Fixture

Mount the Dual Light Fixture onto the rigid conduit using the ¾” NPT thread.  

a.  Mount dual assembly to 3/4” NPT thread fitting or use optional mounting hardware.
b.  Remove free plate.
c.  Connect wires for interfacing cable into provided junction points.

Note: Dual light head is preassembled and wired on T-juntion.

Rigid Conduit

Americas model shown

Содержание AV-OL-KT-A0

Страница 1: ...V1 1 INSTALLATION SERVICE MANUAL AV OL KT A0 Obstruction Lighting Kit FAA A 0 Americas model pictured ...

Страница 2: ...2 Version No Description Date Reviewed Approved Design 1 0 AV OL KT A0 Manual Launch September 2019 P Naidu W Evans M Sugars 1 1 Data updates January 2020 P Naidu W Evans M Sugars ...

Страница 3: ...0 Safety Information 10 6 0 Operation and Setup 11 6 1 System Overview 11 6 2 L 810 F Dual Light Fixture 11 6 3 T1 Controller 13 7 0 Unpacking Installation Wiring and Setup 14 7 1 Unpacking 14 7 2 Installation 14 7 2 1 Tools Required 15 7 2 2 Location 15 7 2 3 Cabling Requirements 16 7 2 4 Factory Configuration 16 7 2 4 Installation Recommendation 16 7 3 Testing Procedure 21 8 0 Maintenance and Se...

Страница 4: ...Avlite has been independently certified as complying with the requirements of ISO 9001 2015 quality management system By taking a few moments to browse through this booklet you will become familiar with the versatility of your lighting kit and be able to maximise its operating function Please remember to complete the Avlite warranty registration card accompanying your product Acronyms and Abbrevia...

Страница 5: ...ments in LED Light Emitting Diode technology as a light source The major advantage of LED s over traditional light sources is well established in that they typically have an operational life in excess of 100 000 hours resulting in substantial savings to maintenance and servicing costs Precision Construction Commitment to investing in the design and construction of injection moulded parts including...

Страница 6: ... an energy efficient and cost effective lighting solution The A 0 Obstruction Light Solution is available in two input power configurations a universal AC 90 264VAC or DC 12 48VDC solar compatible and comes with Star2M monitoring via GSM or SATCOM as options With a range of available brackets and cables utility and telecommunication companies electrical contractors and state and local governments ...

Страница 7: ...ame Sheet Scale Projection Next Ass y 1 5 1 of 1 Model Rev Sealite 0 A B C D E F G 7 8 9 i i d a R r a e n i L X 1 12 8in 325mm 1 x L 810 Dual Global 8 25in 210mm Zone Rev Model Rev ECR No A n w a r D e t a D n o i t p i r c s e D Notes Break all sharp edges 1 Use 3D Model for Machining 2 Refer Drawing for GEO Tol and Dimension Tol 3 Part Nº 4 4 75in 120mm 2 3 0 706 A3 SolidWorks mm Drawn in Units...

Страница 8: ...Control Avlite offers remote Star2M monitoring via GSM or SATCOM Operators can remotely monitor the status of their installation from a compatible device The system can also be configured to send out SMS text messages or e mail alerts to designated operators should alarm conditions be triggered such as low voltage or light failure Please contact Avlite for operational information for the Monitorin...

Страница 9: ...ricas 10 75 272 19 481 4 75 121 5 2 3 L 810 Dual Global 8 5 216 10 3 259 2 5 3 133 2 53 1 15 Control Unit 12 305 12 305 6 152 16 7 3 Mounting L 810 Dual inch pipe thread Control Unit Wall mounted mounting accessories available Certifications and Compliance CE EN61000 6 3 2007 EN61000 6 1 2007 Quality Assurance ISO9001 2015 Protection Rating Junction and Control Box IP65 NEMA4X Lights IP67 FAA L 81...

Страница 10: ...ight Make sure any nearby obstacles do not impede the lights beam pattern When installing comply with all local electrical code s Mains power should always be disconnected when work is being done in close proximity to electrical fittings and electrical work should only be done by a licensed electrician Operate the light only within the indicated electrical ratings and product usage instructions To...

Страница 11: ...nostic checking and an alarm contact for remote monitoring The alarm relay is energized in normal operation and is released if there is an LED or power fault The Control Unit automatically evaluates the L 810 Dual Obstruction Light for operation and performance while providing local and remote display of information and alarms operators can conveniently view the lights real time status from the we...

Страница 12: ...TERMINATE VE VE VE VE GND Tx Rx RS 422 ALARM Relay TxD RxD GND TxD RxD GND RS 232 INTENSITY FULL HALF DUPLEX SW2 ON 1 2 ON 1 2 ON 1 2 Tx Rx RS 422 VE VE VE VE GND TERMINATE VDC 0V GND COMM NO NC VDC 0V GND COMM NO NC POWER ALARM Light Intensity Operation Mode Setting The fixture will be supplied with the FAA compliant optic The FAA compliant model comes pre set to the correct intensity for L 810 s...

Страница 13: ...nterlock which prevents access to the controller while the system is powered on The Controller is available in two input power configurations a universal AC 90 264 VAC or DC 12 48 VDC and comes with remote monitoring via Star2M with either GSM or Satcom telemetry types as options The Control unit comes with an alarm contact for remote monitoring of the Dual Light Fixture which receives the associa...

Страница 14: ...e PCU when the control panel power switch is toggled to the PWR position This may result in damage to the power sources WARNING DO NOT connect directly to the DC output of a generator or any other unregulated power source Connecting to an unregulated source may result in damage WARNING Do not stare into light emitting diode LED beams CAUTION LED lights contain glass components Do Not Drop Always f...

Страница 15: ...r obstruction lights Tools Needed not supplied Flush Cutter Tongue Groove Pliers Silicone Sealant Cable Jacket Trimmer optional Utility Knife Electrical Tape Insulated Terminal Crimper Wire Strippers 10AWG to 18AWG Range 2 5mm Hex Key 2 0mm Flat Blade Precision Screwdriver 2 Phillips Screwdriver Junction Boxes 2 owner supplied or optional purchase Light Mounting Brackets 4 optional purchase Cables...

Страница 16: ...both light heads preassembled and wired on T junction 7 2 5 Installation Recommendation Note The sequence of steps can be adjusted for site requirements 1 Wire and test the system on ground level Conduct a basic functional check to ensure that the lights turn on as expected Refer to Section 7 3 Testing Procedure Reference Point Cable L 810 Dual Obstruction Light Control Unit Power Data Cable 18 AW...

Страница 17: ...ld be plenty of clearance around all sides to allow direct access when the door of the control unit is completely open a Attach the required mounting hardware to the top and bottom of the Control Unit b Mount the Control Unit with the previously attached mounting hardware to the tower or installation structure using the mounting tabs Secure using the required mounting fixtures Note Mounting hardwa...

Страница 18: ...duit using the NPT thread a Mount dual assembly to 3 4 NPT thread fitting or use optional mounting hardware b Remove free plate c Connect wires for interfacing cable into provided junction points Note Dual light head is preassembled and wired on T juntion Rigid Conduit Americas model shown ...

Страница 19: ...les Wiring Instructions Power and Data Cable Connect the red positive conductor from the dual light fixture to the 24VDC terminal block in the Control Unit Connect the black negative conductor from the dual light fixture to the 24VDC terminal block in the Control Unit Connect the green alarm conductor from the dual light fixture to the Alarm terminal block in the Control Unit ...

Страница 20: ...incoming power conductors to the appropriate terminals L1 and L2 on the power switch in the Control Box The grounding conductor will be connected to the green yellow GND terminal block adjacent to the power switch DC Installation Connect the positive conductor to terminal 1 on terminal block 1 Connect the negative conductor to terminal 3 on terminal block 1 ...

Страница 21: ...erence the Product or Configuration Code called out in the Product Configuration and Options section of the corresponding product data sheet Note Avlite recommends that all testing be done during the day 1 Power the system on 2 Check that no circuit breakers have tripped 3 Cover each light fixture in the Dual obstruction light and ensure they turn on 4 Uncover each light fixture in the Dual obstru...

Страница 22: ...ng functions properly use an alternate power source to check the light Replace light if necessary Incorrect Power supply specifications Ensure that the Power supply has the right polarity and voltage range Malfunctioning internal Photocell Cover the photocell and ensure that the light turns ON Cable to Control Unit Check Control Unit to L 810 Dual Obstruction light cable connections at both ends I...