Press and display real height
Press and display real height
Press until 1 appears, release the button, it runs
to corresponding height and displays current position.
Press until 2 appears, release the button, it runs
to corresponding height and displays current position.
Press until 3 appears, release the button, it runs
to corresponding height and displays current position.
Over-heating
protection
Sensorless
alarm
Overload
protection
Rebound
protection
Overvoltage
alarm
Undervoltage
alarm
Step out alarm
Breaking
protection
Metric and
English
unit conversion
Hot: it alarms when continuous working 2 minutes;
clear automatically after resting 18 minutes.
E1: It alarms when motor hall value cannot be inspected;
clear it after press reset or re-power on.
E2: overload alarm when running up, clear automatically
after 3 seconds; overload alarm when running down,
clear it after press reset or re-power on.
E02: it alarms in reversed compression when running;
clear automatically after rebound 4cm; or press any
button to clear when rebounding.
E03: it alarms when voltage is higher than limit value,
clear automatically after voltage reduced to set value.
E05: it alarms when voltage is lower than limit value;
clear automatically after voltage is higher than set value.
E06: it alarms when height difference between left and
right leg exceeds the set value; clear it after re-power on.
It stops and enters protection state when motor lines or
manual control lines are removed or disconnected
accidentally; back to normal after reconnected and alarm
cleared.
Press for 3 seconds and it will display ---, release ,
press until 1 appears, release the button and it
displays current height. (English unit)
Press for 3 seconds and it will display ---, release ,
press until 0 appears, release the button and it
displays current height. (metric unit)
Protection mode (auto lock screen mode)
Press until 4 appears, release the button, it runs
to corresponding height and displays current position.
Save button,used to enter the save height function
After press , the interface flashes and set memory
position, press until H1 appears, release button and
it displays current height.
INSTALLATION
3
6
4
7
Fix the frame 1 (7) with screws (B)
Fix the frame 2 (11) with screws (D)
Secure the side plate (1) with screws (D)
Insert the connecting rod (3) into the frame
Adjust the distance according to the size of the table,
and then tighten the screw (B) with the wrench (E).
5 Mount the desktop (13) with screws (A) on the two side plates
Mount the control box (8) under desktop(13) with screws (A).
Use the screws (A) to install the controller panel(12) under
the desktop. Connect two table boards with the table board
connection board (10).
OPERATION
9
12
6
5
A
C
H
S
M
1
M
2
M
3
Reset
Memory
Position
in condition of E2 or run to basic height position, long
press for 5 seconds, display RES and press still, it
goes down to the lowest and rebound certain height,
reset finish and show basic height.
M
M
M
M
M
E
S=4mm
E
S=4mm
7 Frame(1)
1PCS
D
M6x35 SCREW 6PCS
B
M6x12 SCREW
2PCS
11 Frame(2)
1PCS
1
3 Connecting line 4PCS
B
M6x12 SCREW
16PCS
13
A
M5x16 SCREW
13PCS
10 Table board
connection board
2PCS
8 Connecting rod
A
M5x16 SCREW
2PCS
A
M5x16 SCREW
2PCS
A
M5x16 SCREW
8PCS
B
E
M6x12