background image

Press        and display real height

Press        and display real height

Press         until 1 appears, release the button, it runs 

to corresponding height and displays current position.
Press         until 2 appears, release the button, it runs 

to corresponding height and displays current position.
Press         until 3 appears, release the button, it runs 

to corresponding height and displays current position.

Over-heating 

protection  

Sensorless 

alarm

Overload 

protection

Rebound 

protection

Overvoltage

alarm 

Undervoltage 

alarm  

Step out alarm  

Breaking 

protection

Metric and 

English

 unit conversion

Hot: it alarms when continuous working 2 minutes; 

clear automatically after resting 18 minutes.
E1: It alarms when motor hall value cannot be inspected; 

clear it after press reset or re-power on.
E2: overload alarm when running up, clear automatically

after 3 seconds; overload alarm when running down, 

clear it after press reset or re-power on.
E02: it alarms in reversed compression when running; 

clear automatically after rebound 4cm; or press any 

button to clear when rebounding.
E03: it alarms when voltage is higher than limit value, 

clear automatically after voltage reduced to set value.

E05: it alarms when voltage is lower than limit value; 

clear automatically after voltage is higher than set value.
E06: it alarms when height difference between left and 

right leg exceeds the set value; clear it after re-power on.
It stops and enters protection state when motor lines or 

manual control lines are removed or disconnected 

accidentally; back to normal after reconnected and alarm

cleared.

Press       for 3 seconds and it will display ---, release     ,

press       until 1 appears, release the button and it 

displays current height. (English unit)

Press      for 3 seconds and it will display ---, release      , 

press      until 0 appears, release the button and it 

displays current height. (metric unit)

Protection mode (auto lock screen mode)

Press         until 4 appears, release the button, it runs 

to corresponding height and displays current position.
Save button,used to enter the save height function

After      press  , the interface flashes and set memory 

position, press       until H1 appears, release button and 

it displays current height.

INSTALLATION

3

6

4

7

Fix the frame 1 (7) with screws (B) 

Fix the frame 2 (11) with screws (D) 

Secure the side plate (1) with screws (D) 

Insert the connecting rod (3) into the frame
Adjust the distance according to the size of the table, 

and then tighten the screw (B) with the wrench (E).

5 Mount the desktop (13) with screws (A) on the two side plates

Mount the control box (8) under desktop(13) with screws (A).

Use the screws (A) to install the controller panel(12) under 

the desktop. Connect two table boards with the table board 

connection board (10).

OPERATION

9

12

6

5

A

C

H

S

M

1

M

2

M

3

Reset

Memory

Position

in condition of E2 or run to basic height position, long 

press       for 5 seconds, display RES and press still, it 

goes down to the lowest and rebound certain height, 

reset finish and show basic height.

M

M

M

M

M

E
S=4mm

E

S=4mm

7 Frame(1)

1PCS

    D
M6x35 SCREW 6PCS

    B
M6x12 SCREW

2PCS

11 Frame(2)

1PCS

1

3 Connecting line  4PCS

B
M6x12 SCREW

16PCS

13

     A
M5x16 SCREW

13PCS

10  Table board 
connection board

2PCS

8 Connecting rod

     A
M5x16 SCREW
2PCS

     A

M5x16 SCREW
2PCS

     A
M5x16 SCREW
8PCS

B

E

M6x12

Отзывы: