AVIX Autonomic Mak II Скачать руководство пользователя страница 11

10

• Solar Panel Pole Brackets
• Solar Panel Frame Brackets
• Solar Panel Extension Cable (5m)

Remote access

• AVIX Remote Status & Control Module
• Remote Control (RF) Starter Kit 
• Remote Control (RF) Receiver Kit

Extra accessories

• Laser Warning Sign
• Laser Safety Glasses

9. Troubleshooting

If the AVIX Autonomic is not performing as expected, check the bird-
shaped LED indicator on the back of the AVIX Autonomic enclosure to 
identify the device status (see status list below). Alternatively, check 
the device status in the user interface (see chapter 4; Configuration).

The Autonomic has encountered an error and user action is required. 
If the autonomic was bursting it will automatically try to resolve this 
error every minute. To check the error type, please connect to the 
AVIX Autonomic and check the device status in the user interface (see 
chapter 4.2; Connecting to the device).

7. Spare parts

The following AVIX Autonomic spare parts are available:
• AVIX Autonomic Payload (housing including laser and PCB)
• AVIX Autonomic Housing (enclosure only)
• AVIX Autonomic Rear Cap
• AVIX Autonomic Light Module
• AVIX Autonomic Motor Platform
• AVIX Autonomic Power Switch Module
• AVIX Autonomic Mains Power Adapter

8. Accessories

The following AVIX Autonomic accessories are available.

Mounting system

• Vertical Mounting Bracket
• Horizontal Mounting Frame
• Adjustable Frame Extender
• Power Extension Cable (5m)

Solar charging system

• Battery Box Kit (24V)
• Battery
• Solar Panel

LED color LED appearance Status

OFF Static

OFF (no power): 

No power to AVIX Autonomic.

Blinking white

OFF (powered): 

Press I/O button to switch ON/OFF the Autonomic.

Static purple

Initialization: 

AVIX Autonomic is starting up. If this takes more than 20 seconds, disconnect power and try again.

Static yellow

Standby: 

The Autonomic is switched on, but either no patterns or timeslots are defined or bursting is disabled.

Static green

Bursting (active): 

The Autonomic is running a pattern (caution: laser output).

Static blue

Bursting (pause): 

The AVIX Autonomic is waiting to perform its next pattern.

Blinking blue

Bursting (outside timeslot):

The AVIX Autonomic is waiting to return to its predefined timeslot(s). No patterns will be played.

Blinking red

Error: 

The AVIX Autonomic has encountered an error and user action is required. If the autonomic was 
bursting it will automatically try to resolve this error every minute. To check the error type, please 
connect to the AVIX Autonomic and check the device status in the user interface (see chapter 3).

Static red

Emergency: 

The AVIX Autonomic has stopped working because of the emergency stop on the Power Switch 
Module has been pressed. After the emergency stop has been released, the color of the AVIX 
Autonomic remains red.

Содержание Mak II

Страница 1: ...1 AVIX Autonomic Mark II User manual Version 1 0 ...

Страница 2: ...1 F General overview Package contents 1x 1x 1x 1x 1x B C D E A M I J L K H G O N P ...

Страница 3: ...2 Assembly Figure 1 1 Figure 1 2 ...

Страница 4: ...3 Figure 2 4 Figure 2 2 Figure 2 1 Figure 2 5 Figure 2 3 ...

Страница 5: ...page 6 3 Assembly page 6 4 Configuration page 7 5 Maintenance page 9 6 Warranty page 9 7 Spare parts page 10 8 Accessories page 10 9 Troubleshooting page 10 English A CEE Plug B Mains Power Adapter C Power Switch Module D Motor Platform E Power socket F Payload G Rear Cap H Light Module inside Payload I Beam shutter lock J Laser aperture K Accessory slot L Beam shutter M LED status indicator N Pro...

Страница 6: ...isuse or abuse of the AVIX Autonomic or for the user s failure willful or otherwise to operate the product in a correct and safe manner WARNING Carefully read all safety warnings and all instructions Retain all safety warnings and all instructions for future reference 1 Technical specifications AVIX Autonomic Mark II Laser class wavelength maximum output power divergence diameter at aperture NOHD ...

Страница 7: ...efully before operating the AVIX Autonomic Never project the laser device towards aircraft vessels and vehicles Never project the laser device at humans Never project the laser device into the infinite sky Never project the laser device towards reflective surfaces such as mirrors windows and metallic objects Projecting the laser device towards water can cause distractions The laser safety labels d...

Страница 8: ... tighten the screw connection properly to establish a watertight connection 8 Connect the plug exiting the Mains Power Adapter to the remaining connector on the Power Switch Module Make sure to tighten the screw connection properly to establish a watertight connection 9 Secure the base of the Motor Platform to its supporting structure 3 1 Preparing the mains power connection WARNING Always make su...

Страница 9: ... new waypoint is saved it is always added at the end of the list regardless of what waypoint is selected at the time 10 5 The laser power button which is positioned below the joystick button can be used to deactivate the laser between 2 subsequent waypoints To deactivate the trajectory between two waypoints select the first of the two waypoints and press the laser power button The waypoint will tu...

Страница 10: ...but not limited to the battery For example when waypoint 3 is deactivated the laser will be switched off between waypoints 3 and 4 After waypoint 4 the laser will switch on again 10 6 After completing the pattern press the in the top right corner of the window Step 11 You will return to the dashboard as shown in figure 2 5 on page 3 After completing pattern s and timeslot s press the button at the...

Страница 11: ...vailable Mounting system Vertical Mounting Bracket Horizontal Mounting Frame Adjustable Frame Extender Power Extension Cable 5m Solar charging system Battery Box Kit 24V Battery Solar Panel LED color LED appearance Status OFF Static OFF no power No power to AVIX Autonomic Blinking white OFF powered Press I O button to switch ON OFF the Autonomic Static purple Initialization AVIX Autonomic is start...

Страница 12: ... 230 2030 E hello birdcontrolgroup com W www birdcontrolgroup com W www avix com North American Office 27350 SW 95th Ave Suite 3022 Wilsonville OR 97070 United States T 1 844 406 9280 toll free CONFIDENTIAL AVIX Autonomic is designed and manufactured by Published 05 07 2019 V1 0 ...

Отзывы: