background image

 

 

 

 

 

User’s Manual 

Seneca DA-104 / 208 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Revision 1.0.0 

(May, 2012) 

Содержание Seneca DA-104

Страница 1: ...User s Manual Seneca DA 104 208 Revision 1 0 0 May 2012 ...

Страница 2: ...itten permission of Avitech International Corporation Avitech International Corporation may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Except as expressly written by Avitech International Corporation the furnishing of this document does not give you any license to patents trademarks copyrights or other i...

Страница 3: ...s unable to correct the defect or provide a replacement Product in good working order then the purchaser shall be entitled to recover damages subject to the limitation of liability set forth below LIMITATION OF LIABILITY AVITECH S LIABILITY UNDER THIS WARRANTY SHALL NOT EXCEED THE PURCHASE PRICE PAID FOR THE DEFECTIVE PRODUCT IN NO EVENT SHALL AVITECH BE LIABLE FOR ANY INCIDENTAL SPECIAL OR CONSEQ...

Страница 4: ...ny Product which fails under conditions other than those specifically covered by the Hardware Warranty will be repaired at the price of parts and labor in effect at the time of repair Such repairs are warranted for a period of ninety 90 days from date of reshipment to customer Extended Warranty Options Avitech offers OPTIONAL Extended Warranty plans that provide continuous coverage for the Product...

Страница 5: ...installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits Avit...

Страница 6: ...eutsch German Dieses Produkt entspricht den Bestimmungen der Europäischen Richtlinie 1999 5 EC Ελληνικά Greek To προϊόν αυτό πληροί τις προβλέψεις της Ευρωπαϊκής Οδηγίας 1999 5 EC Íslenska Icelandic Þessi vara stenst reglugerð Evrópska Efnahags Bandalagsins númer 1999 5 EC Italiano Italian Questo prodotto è conforme alla Direttiva Europea 1999 5 EC Norsk Norwegian Dette produktet er i henhold til ...

Страница 7: ...vii Australia and New Zealand C Tick Marking and Compliance Notice Statement of Compliance This product complies with Australia and New Zealand s standards for radio interference ...

Страница 8: ...eneca distribution amplifiers are a powerful supplement to Avitech multiviewers About this Manual This manual contains comprehensive information about your Avitech Seneca DA 104 208 re clocking distribution amplifier to help you operate the device Throughout the manual the following conventions are used to distinguish elements of text NOTE provides additional hints or information that requires spe...

Страница 9: ...nd specifications as well as the external components of your Avitech Seneca DA 104 208 It also guides you through the process of setting up your Seneca for use NOTE Depending on the model you purchased the cabinet color and the look of the accessories may be different from the ones shown in this manual A 1 Package Contents After unpacking the shipping carton you should find these standard items Av...

Страница 10: ...duct Features SD SDI HD 3G distribution Four eight separately buffered outputs Small form factor 100 meter 3G cable equalization 1694a coax 3G HD or SD SDI input auto sensing Transmits all ancillary data 5 V DC power supply power supply sold separately ...

Страница 11: ...ion 270 MB 400 m 1 5 GB 200 m 3 GB 100 m 1694a coax Power supply 5 V DC Power consumption 4 5 watt maximum Dimension L W H 104 110 40 mm 4 1 4 3 1 6 inch NOTE Does not include the BNC connector portion Weight 340 gram 0 7496 lb Environment Temperature Operating 0 C 32 F to 40 C 104 F Storage 10 C 4 F to 50 C 122 F Humidity 0 to 80 relative non condensing Safety regulations FCC CE C Tick Class B Ac...

Страница 12: ...hen no signal is present in the INPUT 1 connector Standby state Glows green when signal is present in INPUT 1 connector 2 upper Glows amber when no signal is present in the INPUT 2 connector Standby state Glows green when signal is present in INPUT 2 connector NOTE Device indicator 2 will not glow for Seneca DA 104 model Dip switches Sets the video routing configuration ...

Страница 13: ...D SD SDI signal for long distance output to monitor display NOTE BNC connectors 2 1 2 2 2 3 and 2 4 are not available for Seneca DA 104 model INPUT 1 2 BNC connector for 3G HD SD SDI video input sources NOTE BNC connector 2 is not available for Seneca DA 104 model Power connector Connects to the power adapter A 6 Input Output Connectors Rear Panel ...

Страница 14: ...5 V DC power to the Seneca 3 For DA 208 only Use the following dip switch settings to effect the following video routing configuration IMPORTANT Step 3 is not applicable for Seneca DA 104 Setting the pin 2 dip switch to ON while pin 1 dip switch is OFF would cause no video output Video Routing Dip Switch Pin Position Pin 1 Pin 2 Automatic routing OFF OFF First input to eight 8 outputs ON OFF Secon...

Страница 15: ...nal will output to OUTPUT 1 1 1 2 1 3 1 4 ports and INPUT 2 s signal will output to OUTPUT 2 1 2 2 2 3 2 4 ports To allow the INPUT 1 signal to output to all the eight 8 output ports OUTPUT 1 1 1 2 1 3 1 4 2 1 2 2 2 3 2 4 then pin 1 must be ON and pin 2 must be OFF To allow the INPUT 2 signal to output to all the eight 8 output ports OUTPUT 1 1 1 2 1 3 1 4 2 1 2 2 2 3 2 4 then pin 1 must be OFF an...