Programming Alarm System Features
All programmable alarm features are accomplished by turning the ignition
key on (or starting the vehicle) and flicking the valet switch on and off a
pre-set number of times.
1. Remove the alarm from valet. Programming cannot be accessed while
the alarm is in the valet mode indicated by the LED on solid red.
2. Select the feature you wish to program from the "Programming Table
for Alarm Features." Note the number of chirps.
3. Turn the ignition key to the "ON" position.
4. Within 10 seconds, begin flicking the valet switch on and off. The siren
will chirp one time each time you flick the switch on then off.
5. Continue flicking the switch on and off until you reach the number of
chirps associated with your chosen feature.
NOTE: Stop on the chirp.
6. After a 3 second pause, you will hear 1 or 2 chirps noted to confirm
that you have changed the setting of that feature.
7. Turn the ignition key off.
8. Repeat steps 1-7 for any other feature you wish to program.
Pro gram ming Ta ble for Alarm Fea tures
Fea ture
Fac tory
Set ting
# of
Chirps
Sec on dary Ac tion
Active/Passive Arming
Passive ON
4
Wait 3 seconds, the siren chirps once for
Active or twice for Passive.
Passive Door Lock
OFF
5
Wait 3 seconds, the siren chirps once for
OFF or twice for ON.
Instant/Delayed Ignition
Control Door Lock
Delayed
6
Wait 3 seconds, the siren chirps twice for
Instant or once for Delayed.
Passive Arming Chirp/Light
Flash Confirmation
ON
7
Wait 3 seconds, the siren chirps once for
OFF or twice for ON.
Long Term Silent
Arm/Disarm
ON
8
Wait 3 seconds, the siren chirps once for
OFF or twice for ON.
Ignition-Controlled
Lock/Unlock
ON
9
Wait 3 seconds, the siren chirps once for
OFF or twice for ON.
Door Lock/Unlock Output
Duration (1 or 3 sec.)
1 second
10
Wait 3 seconds, the siren chirps once for 3
seconds or twice for 1 second.
1 or 2 Pulse Unlock
1 Pulse
11
Wait 3 seconds, the siren chirps once for 2
Pulses or twice for 1 Pulse.
13
Hurricane
2
/AMX78 (2) Installation Manual
Содержание AMX7
Страница 1: ...Hurricane2 Installation Manual 1 Hurricane 2 AMX78 2 Installation Manual ...
Страница 4: ...Wiring Diagram 4 Hurricane 2 AMX78 2 Installation Manual ...
Страница 11: ...11 Hurricane 2 AMX78 2 Installation Manual ...
Страница 12: ...12 Hurricane 2 AMX78 2 Installation Manual ...
Страница 15: ...15 Hurricane 2 AMX78 2 Installation Manual Copyright 1998 Avital Technologies Inc 32 1251 H2IM 98 ...