39
© 2008 Directed Electronics. All rights reserved.
and shuts down. Programmed to the default setting the engine will run
for 12 minutes. If the 24 or 60 minute run time is desired, change this
feature to the two or three flash setting.
3 PARKING LIGHTS—
CONSTANT
/FLASHING:
In the default setting, the parking lights will come on solidly for the entire
run duration. in the flashing setting, the parking lights will flash for the
entire run duration.
4 CRANK TIME—
0.6
/0.8/1.0/1.2/1.4/1.6/1.8/2.0/4.0 Sec-
onds:
If Feature 2 is programmed to the voltage sense setting, the crank
time must be set to the appropriate duration. The default setting is 0.6
second. If a different crank time is desired, select Feature 5 and (while
pressing the Program switch) press the Channel Two button to advance
through the LED Off settings. The unit will flash the LED to indicate which
time is selected. Once the 4.0 second setting is reached the next press
of the Channel Two button will reset the system to the shortest setting.
5 ACTIVATION PULSE COUNT—
1
/2/3 PULSES:
This feature allows the number of pulses to activate the remote start
feature to be changed from 1, 2, or 3 pulses. The pulse count pro-
grammed to start the vehicle will also be the same required to shut
down the remote start.
6 2nd—
IGNITION
/ACCESSORY OUTPUT:
This will allow the PINK/WHITE to be used as a 2
nd
ignition or a
2
nd
accessory.
7 ACCESSORY STATE DURING WAIT-TO-START—
OFF
/ON:
This will allow the programming of the accessory wire during the wait-
Содержание 4113