background image

Thank you for selecting our high-quality portable air conditioner from Avista. 

Before use, please read this entire manual carefully for information regarding 

setting  up  your  portable  A/C,  operating  it,  and  tips  on  regular  maintenance. 

For  any  problems,  please  refer  to  the  Limited  Warranty  Information  at  the 

back of the manual or contact a professional service technician. 

Model# APA08ZCW

 

Portable Air Conditioner 

Owner’s Manual 

Содержание APA08ZCW

Страница 1: ...re manual carefully for information regarding setting up your portable A C operating it and tips on regular maintenance For any problems please refer to the Limited Warranty Information at the back of the manual or contact a professional service technician Model APA08ZCW Portable Air Conditioner Owner s Manual ...

Страница 2: ...emote Control 7 Use of Product Setup and Installation 8 Product Operation 13 Cleaning and Maintenance Water Drainage 15 Maintenance 15 General Troubleshooting Diagnosis of Common Failures 18 Troubleshooting 18 Technical Specification Fuse Parameters 19 Physical Dimensions 20 Limited Warranty Inforamtion 21 Safety Precautions ...

Страница 3: ...e some space around the machine and do not pile up objects around it as it can block the intake exhaust vents Please do not place heavy objects on the machine as this may cause damage to it Safety Precautions The meaning of the icons used in this manual is as follows For you and your families health and safety please do not perform these actions For you and your families health and safety please t...

Страница 4: ...ime please disconnect the power plug Please do not clean this machine with any types of waxes diluents or harsh detergents Only use a lightly damp cloth to wipe it down For your health please do not drink any condensate that has been drained from this machine For your safety only professional service technicians should disassemble assemble or repair this machine 2 ...

Страница 5: ...voltage of the outlet is compatible with the rated requirements of the machine Do not try to fix modify or extend the power cord in any way A grounding socket is required to run this machine Please do not plug or unplug the power plug with wet hands as this may cause an electric shock When disconnecting the power line please do so by pulling on the power plug Do not yank the power cord as this can...

Страница 6: ...fter making a loud noise or there is smoke coming out of the machine please unplug the unit and contact a professional service technician Always power down the machine before unplugging the power cord Please keep the power line away from a heater it can cause electric shock or fire Please make sure to keep heavy objects off the power line as it can cause damage to the cord and lead to electric sho...

Страница 7: ...contact a professional service technician for maintenance Please do not use this machine anywhere near open gasoline or other flammable liquids Please do not allow any water to enter electrical parts of this machine Always unplug the power plug before wiping cleaning moving or replacing internal components of the machine This machine should only be operated by an adult or with adult supervision 5 ...

Страница 8: ...ponents and Parts 1 2 3 4 5 6 7 8 9 10 11 12 13 Air Deflecting Blades Control Panel Exhuast Vent Caster Wheels Power Cord Holder Upper Filter Air Inlet 8 Remote Control Lower Filter Power Cord Drain Plug Exhaust Hose Assembly 13 12 1 2 7 4 7 6 9 3 11 10 5 6 8 ...

Страница 9: ...ressing this button will turn the timer on and off as well as adjust timer setting Fan speed selection button Pressing this button will cycle between high and low fan speeds Timer function button In standby state pressing this button will allow you to set the timer startup time In startup state pressing this button will allow you to set the timer shutdown time Display window This window displays t...

Страница 10: ...n on venting the exhaust air In order to maintain the best performance of the air conditioner please leave a space of at least 20in all around the machine Exhaust hose assembly Exhaust joint Exhaust hose Exhaust flat nozzle Window sealplate assembly Screw Window seal plate 1 Window seal plate 2 Window seal plate 3 20in 20in 20in 8 ...

Страница 11: ...nto the air outlet on rear panel in counter clockwise direction Step 1 1 Measure dimensions of window 2 Adjust the length of the window seal plate so that it fits the dimensions of the window 3 After finding the correct fit for the length of the window seal plate lock it into place by using the included screw 9 ...

Страница 12: ...k First insert Screw Step 4 Click the exhaust hose assembly exhaust flat nozzle end into the window seal plate assembly and secure using the included screw Overall effect diagram after assembly 10 Horizontal Sliding Vertical Sliding ...

Страница 13: ...e by collapsing it as much as possible during operation in order to get the best overall performance Remote control Before using the remote control please install batteries correctly 1 Slide the battery cover off the back of remote control 2 Insert the 2 AAA batteries included in the correct position as shown in this diagram 3 Close the battery cover once the batteries have been installed correctl...

Страница 14: ...ces inside a battery may cause burns or other health hazards If any fluid contacts your skin or clothes please wash thoroughly with water immediately If any fluid is consumed or contacts your mouth please wash out your mouth with water immediately and go to the hospital right away for further inspection 12 ...

Страница 15: ...achine or the remote control to cycle through the different modes until you are in the DRY mode and the indicator light will be on In DRY mode The compressor motor will and automatically turn on shut off to keep the room temperature between 59 or 15 C and 55 or 13 C There is a 3 minute time delay protective function for the compressor In DRY mode the fan will not be adjustable and will only run on...

Страница 16: ...he timer is on In startup state pressing the TIMER button will set the timer shutdown time Press the UP DOWN button to adjust the timer shutdown time 30 minute increments up to 3 hours and then 1 hour increments from 3 hours up to 24 hours and the timer indicator lamp will show if the timer is on Sleep mode In sleep mode the temperature increases by 1 every 2 hours to allow a more comfortable adju...

Страница 17: ...y screen will flash FL with an audible alarm and the compressor will shut off automatically The alarm means the bucket should be drained and here are the steps to do so 1 Disconnect the power cord and remove the exhaust hose assembly 2 Move the air conditioner to an appropriate location where you can pour out the water 3 Pull out the water drain plug in the water outlet to drain all the water insi...

Страница 18: ...water approximate 104 and a few drops of neutral detergent to clean and then place in a cool place to dry 3 Re install the air filter once it has dried 4 Restart the machine to return it to normal operation Attention 5 Please do not clean the air filter with hot water suitable temperature is approximate 104 or irritant detergents such as alcohol gasoline and benzene etc 6 When drying the air filte...

Страница 19: ... accessories such as the exhaust hose and window vent kit and prepare it for storage 6 Take the batteries out of the remote control 7 Place a plastic bag over the entire unit to keep dust from getting into the internals and store in a cool and dry place If the machine is being reused after being idle for a long time or after it has been in storage please make sure to check 1 Check to make sure the...

Страница 20: ...ple problems that you may experience when using this air conditioner If you cannot find the issue in the table below or you cannot fix the problem even after troubleshooting please contact a professional service tech as the issue may require a more thorough inspection of the unit Anti freeze protection if the coil temperature falls below 32 the unit will shut down As the coil temperature rises aga...

Страница 21: ...tioner is not operating very well Air Filters are too dirty Remove the Air filters and clean or replace them Make sure to reinstall the Air Filter prior to operating the A C Air intake or exhaust vent is being partially or completely blocked Remove whatever may be blocking or obstructing any of the air intake or exhaust vents The air conditioner may not be a flat surface Place the A C on a flat sm...

Страница 22: ...The above Technical Dimensions are subject to change without e Physical Dimensions 24 6in 14 2in 12 6in 20 ...

Страница 23: ... office hours are Monday Friday 9 AM to 5PM Central Time Avista Group Corpora on will empt to resolve technical issues over email or via phone If a resolu on is not possible Avista Group Corpor on shall issue a Return Merchandise Authoriza n RMA number for a Return RMA numbers are valid for fi een 15 days from the date of issuance and void therea er You must also 1 Submit proof of purchase in the for...

Страница 24: ...a n or other causes unrelated to defec ve materials or workmanship Serial number is defaced altered or removed Is damaged during shipment Is not used in accordance with the user instru on materials packaged with the Product Is repaired modified or altered by other than Avista Group Corpora on authorized repair centers Avista Group Corpor on reserves the right to refuse and return freight collect Pr...

Страница 25: ...TION LIMITED WARRANTY SET FORTH HEREIN IF DESPITE THE FOREGOING LIMITATIONS FOR ANY REASON AVISTA GROUP CORPORATION BECOMES LIABLE TO YOU FOR DAMAGES INCURRED BY YOU IN CONNECTION WITH THIS AGREEMENT THEN THE LIABILITY OF AVISTA GROUP CORPORATION WILL BE LIMITED TO THE AMOUNT EQUAL TO THE INVOICE AMOUNT PAID BY YOU TO AVISTA GROUP CORPORATION OR AN AVISTA GROUP CORPORATION AUTHORIZED RESELLER FOR ...

Отзывы: