Number of channels 

4 (4 separate A/D converters)

ADC type 

Delta-Sigma architecture with 
integrated adaptive anti-aliasing filter

Resolution 

16 bit or 8 bit

Maximum aggregate 
sample rate

4 x 750 kHz / 16 bit

Sample rates [kHz] 

750, 500, 375, 300, 250, 214, 187.5,
166.6, 150, 125, 100, 75, 62.5, 50

Frequency response (-3dB) 

20 Hz - 370 kHz

Input sensitivity (max trim) 

-43.2dBV = -41 dBu = 6.9 mVrms

Input sensitivity (min trim) 

-3.2dBV = -1 dBu = 0.69 Vrms

Gain adjustment potentiometer  40 dB continuous range 

Input impedance 

50 kOhm

Analog input connectors 

female XLR-5 sockets

Other inputs 

external trigger (TTL-compatible), 
4 digital inputs (TTL-compatible), 
SYNC in/out

Computer interface 

USB 2.0, 
isochronous high-speed mode

Supply current 
(drawn from the USB) 

450mA

Physical dimensions (W/H/D)  163 x 42 x 125 mm
Weight 

620 g

Specifications

In the interest of product improvement, the specifications and/or 
appearance of this unit are subject to change without notice.

Windows PC with at least one USB 2.0 port, Intel Core i5 processor 
or higher, running Windows Vista / 7 / 8 / 10

Computer requirements

Содержание UltraSoundGate 416H

Страница 1: ...d one device must be configured as the master see section RECORDER USGH Settings for details on this 6 TRG button This button can control the wav file recording process in the RECORDER software To enable this mode of operation one of the following Trigger source options must be selected from the configuration dialog box USG TRG button auto hold Pressing the button for more than 2 seconds will acti...

Страница 2: ...ent the proper operation of the A D converters Enable band pass mode At a few sample rates 50 62 5 75 150 187 5 250 and 375 kHz the A D converters can be configured for a special band pass mode in which the analog input bandwidth ranges from fs 2 to fs instead of the normal mode from 0 to fs 2 This option can be advantageous for monitoring applications that require minimal WAV files sizes Note tha...

Страница 3: ...ate and the number of channels is high In order to simplify the operation of the Avisoft RECORDER software in the field a link to RECORDER USGH may be added to the Windows Startup folder Start All Programs Startup Additionally the Avisoft RECORDER option Monitoring Autostart should be activated This arrangement will start the monitoring process automatically after booting the laptop computer the U...

Страница 4: ...adjustment potentiometer 40 dB continuous range Input impedance 50 kOhm Analog input connectors female XLR 5 sockets Other inputs external trigger TTL compatible 4 digital inputs TTL compatible SYNC in out Computer interface USB 2 0 isochronous high speed mode Supply current drawn from the USB 450mA Physical dimensions W H D 163 x 42 x 125 mm Weight 620 g Specifications In the interest of product ...

Страница 5: ... x 750 kHz 16 bit Sample rates kHz 750 500 375 300 250 214 187 5 166 6 150 125 100 75 62 5 50 Frequency response 3dB 20 Hz 370 kHz Input sensitivity max trim 28 4 dBV 26 2 dBu 38 0 mVrms Input sensitivity min trim 1 6 dBV 3 8 dBu 1 2 Vrms Gain adjustment potentiometer 30 dB range with 3 dB increments Input impedance 50 kOhm Analog input connectors female XLR 5 sockets Other inputs external trigger...

Отзывы: