background image

GREEN LED

OFF

ON

FLASHING

No external 

connection

External 

comunication 

established

Local intercom 

communication 

established

RED LED

OFF

ON

FLASHING

Local audio disabled

Local audio enabled

Automatic 

disconnection 

timeout

DEVICE OPERATION

Pressing the button for three seconds will activate an external alarm call. Both LEDs will 
turn on.

Once the external call has been placed an additional local intercom connection will 
be enabled to allow for communication with all connected audio modules and the 
external receiver. The local intercom connection will automatically be disabled when 
the external call is hung up.

Alternatively, pressing the button for 1 second will enable or disable a local intercom 
connection only. The red LED will indicate this.

After an alarm press is initiated there is a 15 minute time out period. During this time the 
Triphony Unit will activate local audio if there is an incoming call. The Triphony Unit will 
automatically swtich back to standby mode when the 15 minutes is up.

EXAMPLE SYSTEM ARCHITECTURE

Lift 
Controller

Lift car

Lift shaft

DCP

Triphony Unit

Digital Audio Unit 

Отзывы: