Old Programming Mode
The old programming menu is still available on the Memcom
+
unit. To access this mode of programming, from the idle
screen, simply enter the old programming passcode
(default- *1234#).
Old Menu Structure
Quick Start Guide to programming…
Programming options for the type of Memcom
+
Alarm / Software Calls
*11 1st (Alarm Tel Number) # Program 1st Alarm Number
*15 5th (telephone alarm number) **1# Program Technical Alarm Number
*16 6th (telephone alarm number) **1# Program EN81-28 Background Test Call Number
Suffix
Pre-fix
#
Guided message for call centre
**0#
No guided message for call centre.
**1#
Memcom
+
ETR Software or GlobalNet
**3#
P100 Protocol (not compatible with ETR / GlobalNet
**4#
Use when the Memcom
+
is connected to a hotline.
**6#
Contact ID protocol (not compatible with ETR / GlobalNet)
*23 Volume TOC 5, COP 0 Adjustable between 0-9 (0 = minimum setting)
*41 Location message: 1: Play Location 2: Record Location Message
*26 Hardware
Defaults: 12 TOC Version 8 COP Version
1 = EN81-28 operating mode opts
2 = Service Input = Tech.2
4 = Disable internal microphone
8 = Consecutive dial mode
16 = Enable Memcom GSM module
64 = Alarm Input N/C
128 = Czech, Greek, Italian and Singaporean
dial tone cadences for use with multiple
Memcoms only
256 = Service Input as Alarm Activation
512 = COP Accessory attached (450 200 & 450
250).
Any combination can be programmed. Enter
sum of the numbers of the options required.
*27 Hardware Monitoring
Default: 39
1 = PSU monitoring
2 = Battery supply
4 = Phone line, (Do not use if
connected to a hotline)
8 = GSM Low signal
16 = GSM No signal
32 = Microphone/speaker test
64 = Power Logging
Any combination can be
programmed. Enter sum of the
numbers of the options required.
Exiting Programming
Press # to return to the programming home screen, then enter one of the following exit codes...
*01# Exit programming without making an alarm call
*03# Exit programming and call Alarm number 6 EN81-28
*021# Exit programming and call Alarm number 1 only
*035# Exit programming and call Alarm Number 5 Technical Alarm
17
Memco
is a brand of Avire
Avire Global Pte Ltd
Unit 16
69-73 O’Riordan Street
Alexandria
NSW 2015
T:
296691102
F:
269631137
E:
W:
www.memco-global.com
W:
www.avire-global.com