Indicator lights and button/switch function table
Symbol
Function
State
Description
Color
PWR
Work
indicator
On
Normal
Green
Off
Switch has no power supply or initialization failure
PoE
PoE
On
Normal
Green
Blink
PD device failure or power overload
Off
No connected PD or switch has no power
Link
Network
On
Link is established and ready to use
Yellow
Blink
Link port is receiving/sending data
Off
Link failure or port failure
Function switches
E:
default OFF. Can support 100m power supply and communication; when dial E is set to ON, the switch
can support 10M/250m long-distance power supply and communication, however, 4 PoE ports are isolated
from each other. There will be no communication between PoE ports.
D:
default OFF. After communication between ports is interrupted, the connection won’t be reestablished
automatically. The user needs to manually enter IP addresses to connect devices again; when dial D is set to
ON, communication can be resumed automatically once the interrupted connection is reestablished.
P:
default ON. PoE power indicator light will light up in different colors. Power consumption
≤
25% (green
block), 25%<P
≤
50% (yellow block), 50%<P
≤
75% (orange block), P>75% (red block); Port 1 has the top
priority regarding the power output.