23
Serial Port Communication Control
In normal working state, user can control the camera through RS485 (VISCA IN) cable. The parameter of RS485 is list as
below:
Baud rate: 2400/4800/9600/115200/second
Start Bit
:
1 bit
;
Data Bit
:
8 bit
;
Stop Bit
:
1 bit
;
Verification Bit
:
None.
4.1 VISCA Protocol List
VISCA Protocol List
Ack/Completion Message
Command packet
Remark
ACK
z0 41 FF
Returned when the command is accepted.
Completion
z0 51 FF
Returned when the command has been executed.
z = device a 8
Error Messages
Command packet
Remark
Syntax Error
z0 60 02 FF
Returned when the command format is different or when a
command with illegal command parameters is accepted
Command Not
Executable
z0 61 41 FF
Returned when a command cannot be executed due to current
conditions. For example, when commands controlling the focus
manually are received during auto focus.
Camera Control Command
Command
Function
Command Package
Remark
IF_Clear
Broadcast
88 01 00 01 FF
I/F Clear
CommandCancel
8x 21 FF
CAM_Power
On
8x 01 04 00 02 FF
Power ON/OFF
Off
8x 01 04 00 03 FF
CAM_Zoom
Stop
8x 01 04 07 00 FF
Tele (Standard)
8x 01 04 07 02 FF
Wide (Standard)
8x 01 04 07 03 FF
Tele (Variable)
8x 01 04 07 2p FF
p = 0(low) - 7(high)
Wide (Variable)
8x 01 04 07 3p FF
Direct
8x 01 04 47 0p 0q 0r 0s FF
pqrs: Zoom Position
Содержание AV-1180
Страница 6: ...2 1 2 Product Overview...
Страница 18: ...14...