Use Cat-5e Unshielded Twisted Pair (UTP) cables or better for all A-Net 

applications. 

The  RJ45  connector  looks  similar  to  the  connectors  found  on  a  telephone 

system, only larger. The twisting of the wire pairs helps to shield the cable 

from  unwanted  interference  from  electrical  fields  or  radio  interference 

(sometimes referred to as “RF”). Cat‑5 cabling supports frequencies up to 100 

MHz and speeds up to 1000 Mbps. 

RJ45 Jack

Cat-5 Cable

Cat-5 Cables 

The  cables  used  with  your  Aviom  system  are  interchangeable  with  any 

standard  Category  5e  (Cat‑5e)  cables.  If  you  need  a  longer  cable  for  a 

particular application, any computer store should be able to supply you with 

an appropriate cable. A qualified technician should be able to build custom 

cables to any length (up to the maximum of 500 feet (150 meters) between 

components).

For fixed or permanent installations, you have the option of running Cat‑5 

cables  inside  walls  and  terminating  them  with  readily  available  wall  panel 

connectors  that  include  the  RJ45  jack.  (Solid  wire  is  recommended  for 

permanent installations.)

In addition to standard Category 5e cables, Category 6 (Cat‑6) cables can also 

be used.

P

   N

ote

When purchasing Category 5e cables, be sure to buy only standard 

Cat‑5e UTP cables, not those sold as crossover cables. A crossover 

cable is used for file transfer between two computers. A crossover 

cable is not compatible with your Aviom equipment.

Cable Lengths

Cat‑5e  cables  used  with  your  Aviom  products  can  be  up  to  500  feet 

(approximately 150 meters) in length between devices. The maximum cable 

length  specification  applies  to  the  cable  connected  between  the  AN‑16/i 

Input  Module  and  the  first  Pro16  output  module  (or  Personal  Mixer)  in 

your system as well as for cable runs between each additional Pro16 A‑Net 

Содержание A-16D A-Net

Страница 1: ...9310 1002 0001F rev 2 00 2009 Aviom Inc User Guide PRO A N e t D i s t r i b u t o r D i s t r i b u t e u r d A N e t PRO A N e t D i s t r i b u t o r D i s t r i b u t e u r d A N e t...

Страница 2: ...t to change without notice Notice of Rights All rights reserved No part of this document may be reproduced or transmitted in any form or by any means electronic mechanical photocopy recording or other...

Страница 3: ...cles and the point where they exit the apparatus Only use attachments accessories specified by the manufacturer 11 Use only with the cart stand tripod bracket or table specified by 12 the manufacturer...

Страница 4: ...N Using any audio system at high volume levels can cause permanent damage to your hearing Set your system volume as low as possible Avoid prolonged exposure to excessive sound pressure levels IMPORTAN...

Страница 5: ...ress phone number description of the problem and copy of the original bill of sale with the shipment The Return Authorization number should be written on the outside of the box THIS LIMITED WARRANTY G...

Страница 6: ...web site at www aviom com To fulfill warranty requirements your Aviom product should be serviced only at an authorized Aviom service center The Aviom serial number label must appear on the outside of...

Страница 7: ...pplies 6 Rack Mounting 7 Cleaning and Maintenance Information 8 A 16D Front Panel 9 A 16D Rear Panel 9 Connecting the A 16D 10 A 16D Front Panel 10 Front Panel LED Indicators 10 A Net Input 10 A Net O...

Страница 8: ...t signal from any A Net product including other A Net Distributors via industry standard Cat 5e cables Each A 16D accepts one A Net input and provides eight A Net outputs The A 16D A Net Distributor e...

Страница 9: ...terface cards Compatibility with Pro64 Many Pro16 products can be connected to a Pro64 A Net system with the addition of the ASI A Net Systems Interface The ASI translates Pro64 A Net data into Pro16...

Страница 10: ...using readily available components An unlimited number of A Net devices can be used in a system Ease in spanning long distances between system compo nents P Note While the Cat 5e cables and connectors...

Страница 11: ...the maximum of 500 feet 150 meters between components For fixed or permanent installations you have the option of running Cat 5 cables inside walls and terminating them with readily available wall pan...

Страница 12: ...lers used or passive wall panel interconnections in use Use Cat 5e cable for best performance wherever possible Stranded or solid Cat 5e cable can be used When using the optional AN 16SBR System Bridg...

Страница 13: ...circuits that may help protect your equipment Other options for protection of your equipment include the use of an AC line conditioner or a battery backup system sometimes referred to as an uninterrup...

Страница 14: ...placed side by side on a standard rack shelf These shelves are available as an accessory from many audio and studio suppliers There are two shelf mounting holes in the bottom panel of the A 16D The ho...

Страница 15: ...an use a cloth slightly dampened with water or with a mild detergent When cleaning your Aviom products never spray cleaners directly onto the product surfaces Instead spray a small amount of the clean...

Страница 16: ...A Net Distributor User Guide A 16D Front Panel A 16D Rear Panel Function 1 Main A Net Input 2 Power LED 3 A Net Active LED 4 Remote DC Power LEDs 5 Parallel A Net Outputs 6 DC power supply inputs 7 Po...

Страница 17: ...he AN 16 i Input Module AN 16 i M Mic Input Module the Y1 console interface card when using a Yamaha digital mixing console or compatible third party digital console interface cards You can expand a P...

Страница 18: ...onnected directly to the A Net outputs of the front of the A 16D Connect the A Net Out jack of the input module to the A Net In jack on the A 16D A Net Distributor using a Cat 5e cable A Net Outputs T...

Страница 19: ...ixers connected to the A 16D Up to eight A 16 Personal Mixers can be powered in this manner There are nine DC power connectors on the A 16D rear panel The eight on the left side are for adding remote...

Страница 20: ...e supplied via the Cat 5 cable to A 16II Personal Mixers connected to these ports Personal Mixers connected to the remaining A Net ports must use their power supplies locally DC power supplies shown i...

Страница 21: ...You cannot power the A 16D Distributor via the Cat 5e cable Only Personal Mixers can use this feature From A Net input module A second A 16D is added by connecting A Net output port 8 on the first A 1...

Страница 22: ...d system that includes both stereo personal monitoring and discreet single channel distribution Phones Lines Out DC Power 18 24 VDC Regulated 500 mA T Left R Right S Ground Out A Net In From A Net inp...

Страница 23: ...16 A 16D A Net Distributor User Guide From A Net input module Cat 5e up to 500 feet 150 meters Cat 5e up to 500 feet 150 meters A Net is extended by adding an A 16D between a pair of output modules...

Страница 24: ...Voltage for Personal Mixers 18 24 VDC 0 5 amp transmitted over the Cat 5e cable DC Power Jacks 1 main 8 aux one per A Net output plug size 2 mm Latency 0 880 msec measured from analog input to analog...

Страница 25: ...18 A 16D A Net Distributor User Guide Dimensions...

Страница 26: ...19 A 16D A Net Distributor User Guide...

Страница 27: ...ertifications ii Cleaning and Maintenance 8 Compatibility with Pro64 2 computer network 3 Connecting a Mixer 10 Connecting the A 16D 10 console card 10 console interface card 2 crossover cables 4 D da...

Страница 28: ...ering a Personal Mixer 12 Power LED 9 power supply 9 plug size 6 replacing 6 power supply polarity 7 Pro16 3 Pro64 2 R Rack Mounting 7 Rear Panel 9 12 Remote DC Power 9 12 replace the power supply 6 R...

Страница 29: ...n will be kept confidential Model Number Product Serial Number Model Number Product Serial Number Model Number Product Serial Number Model Number Product Serial Number Date Purchased Dealer Name Deale...

Страница 30: ...1157 Phoenixville Pike Suite 201 West Chester PA 19380 Voice 1 610 738 9005 Fax 1 610 738 9950 www Aviom com...