6. Mount the ACM Embedded Controller as shown below (the arrows show screws).
ACM
Embedded
Controller
V100
Address 0
V100
Address 1
7. Mount the V100 subpanels as shown in step 4.
8. Using a small slotted screwdriver gently turn the V100 addresses as follows:
l
Set the top V100 to Address 0 (as shown in step 4).
l
Set the bottom V100 to Address 1 (as shown in step 4).
/05&
Always use stranded wires - the recommended gauges are:
l
18 AWG – low voltage power wires.
l
22 AWG – data wires.
Configure and Wire Data
Follow the steps below to configure and wire the ACM Embedded Controller:
1. Connect the white enclosure tamper wires to /- on the ACM Embedded Controller. Polarity does
not matter.
ACM
EMBEDDED
CONTROLLER
14
Configure and Wire Data