The Approved Model List for the STC will indicate if an aircraft is required to install wire
harness overbraid on the IFD5XX wiring. Note: Overbraid is not required on VFR only
installations as defined in Section 2.4.1.
4.5.3 Copper Overbraid Installation
The copper overbraid must be a minimum 90% optical coverage per ASTM-B-33. The
overbraid must be grounded at both ends. If the aircraft wiring passes through wire
disconnects or bulkheads, the overbraid should be continued on each segment.
The wire harness overbraid should also be installed per FAA AC 43.13-1B Chapter 11-189.
4.6 IFD5XX Connectors
The following special tools may be needed during installation of the IFD5XX:
IFD5XX
Connector
Number
Connector
Part number
Contact Part
Numbers
Crimp
Tool
Die/
Positioner
Extraction
Tool
Insertion
Tool
P1001
M24308/4- 268( )
M39029/58-360
(ORG/BLU/BLK)
M22520/02-
01
M22520/2-09
M81969-1-04
M81969/1-04
P1002
M24308/2-3( )
M39029/63-368
(ORG/BLU/GRY)
M22520/02-
01
M22520/2-08 M81969/1-02
M81969/1-02
P1006
M24308/4- 266( )
M39029/58-360
(ORG/BLU/BLK)
M22520/02-
01
M22520/2-09
M81969-1-04
M81969/1-04
P1050
M24308/4- 268( )
M39029/58-360
(ORG/BLU/BLK)
M22520/02-
01
M22520/2-09
M81969-1-04
M81969/1-04
Ground Block
583861-7
(TE
Connectivity)
5-583853-4
(TE Connectivity)
91535-1
(TE
Connectivity
)
91073-1
(TE
Connectivity
)
Table 21: D-Sub Connector Tools
4.7 Byteflight Digital Data Bus Consideration
– Dual IFD Installations
Dual IFD installations use a Byteflight digital Databus protocol when connected via RS-232
Channel 3 and configured for CrossSync. The following must be considered for replacement
and new installations.
4.7.1 Databus Wiring - Replacement Installations
For installations that are replacing two previously connected GNS4xx/5xx systems, the
Byteflight digital Databus is capable of using the pre-existing wiring between the two pre-
existing trays with no additional wiring or modifications required. All bus termination is
built into the IFD units. However, the existing wire length on the CrossSync connection must
not exceed 8 feet in length on IFD5XX RS-232 Channel 3 on P1001. Installations with longer
installation lengths between IFD5XX units must use Byteflight cable. The ByteFlight wire is
available from Avidyne, reference Table 15.
Содержание IFD540
Страница 1: ......
Страница 124: ...IFD5XX Installation Manual 600 00299 000 Page 124 of 198 Revision 02 Figure C 34 Instrument Panel Cutout ...
Страница 125: ...IFD5XX Installation Manual 600 00299 000 Page 125 of 198 Revision 02 Figure C 35 GPS Antenna Installation Forward ...
Страница 127: ...IFD5XX Installation Manual 600 00299 000 Page 127 of 198 Revision 02 Figure C 37 GPS Antenna Doubler ...
Страница 198: ...600 00299 000 Copyright 2014 Avidyne Corporation Rev 02 ...