F - MAINTENANCE AND UPKEEP
Check the condition of the
electronic card (removal of
dust, insects, etc.)
x
x
x
x
Check the controls (intercoms,
keypad, push button)
x
x
x
x
Check the batteries of the
remote controls
x
x
x
x
Check the motor support
(deformation, etc.) and the
fasteners
x
x
x
x
* do not use grease, as it tends to attract dust or dirt
** please note that adjustments made in summer may need to be changed according to the season (more wind in autumn, frost
in winter, etc.)
2. OPERATING INDICATORS
This system has two operating indicators: the battery charge level (optional) and the history of events.
OK
Charge batterie
PROG
OK
Code 1
PROG
–
+
Code 2
Code 3
–
+
Code 4
–
+
OK 3s
efface historique
du plus
récent
au plus
ancien
MENU
0
(dernière
erreur
)
L1
L2
L3
L4
L1
L2
L3
L4
L1
L2
L3
L4
L1
L2
L3
L4
historique des événements
L1
L2
L3
L4
OK
2.1. History of events and error codes
• During operation, events may occur that may be malfunctions of the motor drive or consequences of user
actions.
• Each event has a different code.
• This code is displayed by a combination of red LEDs that are on, off or flashing on the
MENU 0
display.
• When
OK
or
PROG
are pressed, this code is deleted. However, the last 4 codes generated are memorised,
and can be viewed in a history.
• To access them, press
OK
twice, then use the “
+
” and “–” buttons to scroll through the memorised codes.