![AVGear AVG-UHMS66PRO Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/avgear/avg-uhms66pro/avg-uhms66pro_user-manual_3030943024.webp)
AVG-UHMS66PRO
5.3.6. RS232 Communication Commands
Baud rate: 9600 Data bit: 8 Stop bit: 1 Parity bit: none
Command
Function
Feedback Example
System Commands
/*Type;
Query the models information.
UHMS66PRO
/%Lock;
Lock the front panel buttons on the
Matrix.
System Locked!
/%Unlock;
Unlock the front panel buttons on the
Matrix.
System Unlock!
/^Version;
Query the version of firmware
VX.X.X
/:MessageOff;
Turn off the feedback command from
the com port. It will only show simple
words like “SWITCH OK!”.
/:MessageOff;
/:MessageOn;
Turn on the feedback command from
the com port.
/:MessageOn;
Demo.
Switch to the “demo” mode, route input
and output in turn like1B1, 1B2, …6B5,
6B6, 1B1… and so on .The switching
interval is 2 seconds.
Demo Mode
AV: 1-> 1
AV: 1-> 2
AV: 1-> 3
AV: 1-> 4
AV: 1-> 5
AV: 1-> 6
AV: 2-> 1
…
Undo.
To cancel the previous operation.
Undo Ok!
Out 1 2 3 4
In 1 1 1 1
Out 5 6
In 1 1
Operation Commands
Содержание AVG-UHMS66PRO
Страница 42: ...AVG UHMS66PRO 7 Panel Drawing ...