AVG-FMM12
/+[Y]/[X]:******.
Set communication between PC
and HDBaseT receiver.
•
Y is for RS232 port (connect with
RS232 port of HDBaseT
receiver)
a.
Y = 1~12, send this command to
the corresponding HDBaseT
receiver to control far-end
device.
b.
Y = A~L, send this command to
the corresponding HDBaseT
receiver when FMM12 is
powered on
c.
Y = M~X, send this command to
the corresponding HDBaseT
receiver when FMM12 is
powered off
•
X is for baud rate, its value
ranges from 1 to 7 (1--2400, 2--
4800, 3--9600, 4--19200, 5--
38400, 6—57600, 7--115200)
•
***** is for data (max 48 Byte)
601%
Volume of MIC : 60
(****** and feedback
from HDBT receiver)
%0911.
Reset factory default
Factory Default
Query Command
Status[x].
Query the respective input to output
[x]
AV:01-> 02
Status.
Query respective inputs for all
outputs
AV:01->02
AV:03->06
… …
CheckInKatype.
Get the input signal card type
*-- no available input signal card/
output card, 1--VGA, 2--DVI, 4--BT,
5--SDI, 6--HDMI
Channel
IN:*11*4**11*4*.
CheckOutKatype.
Get the output signal card type
*-- no available output signal card/
input card, 1--VGA, 2--DVI, 4--BT,
6--HDMI
Channel
OUT:***4*62**1**.
Содержание AVG-FMM12