CPU Memory
Memory Types
A PLC system handles many numbers representing different types of information
regarding processes/machine parameters. These processes/machine parameters
may be anything from status of the input or output devices, timers/counters, or
other data values. Before you start programming the
EZTouch I/O Flex
, it would
be
helpful if you took a moment to familiarize yourself with how the
system
represents and stores the various types of data. Each PLC manufacturer has
their
own conventions for this process in their PLCs.
The
section outlines the specific memory types used in
the
EZTouch I/O Flex
in greater detail. The memory types can be used to store
a
variety of information and can be used within various RLL instructions. See a
description of each of the memory types below:
o
Discrete Memory Type
A discrete memory type is one bit that can be either a 1 or a 0 (On or Off).
Discrete memory area is used for inputs, outputs, control relays, and
timer/counter bits.
o
A word memory type is a 16-bit location that is normally used to store
and manipulate numeric or ASCII data. A word memory location is also
called a Register.
The following table displays all the Register/Discrete types supported by the
EZTouch I/O Flex
along with their address range, syntax, etc.
EZTouch I/O Flex
Memory Map
SYNTAX: TAAAA
T - TYPE
AAAA - Address of Memory Type in Decimal
MEMORY TYPE
ADDRESS
RANGE
I/O TYPE
VALUE TYPE
SYNTAX
EXAMPLES
DISCRETES / REGISTERS
RETAINED ON POWER CYCLE
I- Discrete Inputs
1-128
READ_ONLY
DISCRETE
I5
NONE
O- Discrete Outputs
1-128
READ_WRITE
DISCRETE
O6
O1- O128
S- Discrete Internals
1-1024
READ_WRITE
DISCRETE
S4
S1- S1024
IR- Input Register
1-64
READ_ONLY
WORD
1R3
NONE
OR- Output Register
1-64
READ_WRITE
WORD
OR2
OR1 - OR64
R- Register Internals
1-8192
READ_WRITE
WORD
R100
R1
– R
8192
SR- System Registers
1-64
READ_WRITE
WORD
SR1
SR1
–SR
64
SD- System Discretes
1-64
READ_WRITE
DISCRETE
SD10
SD1
–SD
64
XR- Index Registers
1-4
READ_WRITE
WORD
XR10
NONE
#
R – Value Registers
1-4
READ_WRITE
WORD
#R6
#R1 - #R4
Note: Does not Support Access to a Bit of Word (E.g.: R100/ 0, R100/5
…etc
)
Содержание 6" EZTouch I/O Flex
Страница 1: ...Copyright 2015 by AVG Automation All Rights Reserved EZTouch I O Flex ...
Страница 21: ...EZTouch I O Flex 21 64 Touch I O with Micro Terminal Layout ...
Страница 22: ...EZTouch I O Flex 22 64 Terminal Pinouts ...
Страница 23: ...EZTouch I O Flex 23 64 ...
Страница 26: ...EZTouch I O Flex 26 64 Analog I O Specifications ...
Страница 27: ...EZTouch I O Flex 27 64 ...
Страница 28: ...EZTouch I O Flex 28 64 Touch I O with Nano Terminal Layout ...
Страница 29: ...EZTouch I O Flex 29 64 Terminal Pinouts ...