Instructions for use of the AVEX P3 R antiparticle filter, intended for use with 

quarter-masks, half-masks, full face masks and filter ventilation units. 

FILTER TYPE: P3 R/ TH3 P R SL / TM3 P R SL 

Before using the filter, carry out a visual inspection and ensure that the filter is 
not damaged or used. Check that the connection thread of the protective device 
matches  the  thread  of  the  filter  and  remove  the  filter  from  the  packaging. 
Remove  the  covers  from  the  filter  thread  and  inlet,  screw  the  filter  onto  the 
connective chamber of the protective face unit or filter ventilation unit. Save the 
covers as they will be used to close the filter after use. Before and during use, 
the type and concentration of the harmful substances must be known. Oxygen 
concentration  in  the  surrounding  atmosphere  must  be  at  least  17%  vol.  The 
duration of effective use of the filter depends on the type and concentration of 
the harmful substances, relative air humidity, the amount and the size of the 
particles. If the breathing resistance increases due to  clogging, the filter must 
always be replaced. When used against common, non-toxic particles, the filter 
can be used repeatedly (R). After use, close the filter inlet and outlet with the 
covers.  The  used  filter  is  treated  as  hazardous  waste  according  to  the 
categorisation of the (harmful) substance against which the filter had been used. 
The filter may be disposed of by incineration in a chemical waste incinerator or 
deposited in a suitable chemical waste landfill. 

Restrictions: 

The filter must not be long-

term exposed to direct radiant heat above 100°C. 

During use, do not subject the filter to open fire.  Failure to follow the conditions 
of  use  may  result  in  irreversible  damage  and  filter  malfunction.  When  used 
against dangerous microorganisms, highly toxic or radioactive particles, the filter 
is intended for single used only. The maximum air flow per filter is 95 litres/min. 

Use: 

The filter, in conjunction with a suitable type of protective equipment, ensured 
protection against solid and liquid aerosols, fibro-plastic particles 

(e.g. asbestos), dust, smoke and dangerous microorganisms (bacteria, viruses, 
fungal spores, rickettsias, etc.) 

If the breathing resistance increases due to clogging, the filter must always be 
replaced. When used against common, non-toxic particles, the filter can be used 
repeatedly (R). After use, close the filter inlet and outlet with the covers. 