3.2 Accumulation weighing application
Using Entered Tare
To perform a net weighment using entered tare, the following steps describe a typical
operation:
1.
With no weight on the scale, if the display does not read
0
press
ZERO
…
0
is displayed and the
center-of-zer
o annunciator lights.
2.
Key in the tare value of the container or box that will be used to hold the
material that requires a net weight value, and press
TARE
…
Tare weight is displayed as a negative value and the
NET
weight is
display and the PT annunciator lights.
3.
Place the container or box and material to be weighed on the scale …
Net weight of material is displayed.
4.
If repeated weighments use the same tared item, you do not need to establish
a new tare value as described in step
5.
To remove the tare weight from the scale, enter
0
, then press
TARE
…
The tare is cleared and the scale is in gross weigh mode.
Using Preset Tare
Preset tares are entered in a password protected menu. Refer to details described in
the
. There are 10 tare values stored in memory. To
perform a net weighment using one of the preset tares, follow these steps:
1.
With no weight on the scale, if the display does not read
0
press
ZERO
…
0
is displayed and the
center-of-zero
annunciator lights.
2.
Press
TARE
…
EntEr
is displayed.
3.
Key in the desired preset tare number and press
ZERO
…
Tare weight is displayed as a negative value and the net weight is
displayed and the PT annunciator lights.
4.
Place container or box and material to be weighed on the scale …
Net weight of material is displayed.
If gross weight is not at 0, press the
ZERO
key; then press the
TARE
key to clear the
tare value.
Press and hold
TARE
for 3 seconds and the display will show
cLEArEd
and the Tare
weight is cleared.