ZK830 Counting Scale User Instructions
19
3.2 Counting application
c
If the sample weight was not enough or if the weight was unstable,
tMout
is briefly displayed and the display returns to gross weighing
mode. Repeat steps
using a larger sample size. The
TARE
key can be used to abort the sampling process, if necessary.
5.
Place the parts on the scale to be counted. If enabled you can accumulate the
count and number of transactions by pressing
while in count mode.
6.
If enabled, press and hold
for three seconds to print and/or clear the
active count total. These functions are enabled or disabled in a password
protected menu.
3.2.8 Counting in bulk mode
With the count application in bulk mode active, follow these steps to count:
1.
Press
ZERO
to zero the scale, if necessary.
2.
Use a tare method to tare a container, if necessary. See
3.
Press the
SAMPLE
key…
SAMPLinG
is briefly displayed. This means the indicator is zeroing
itself. A message,
Add
XX
, is then displayed.
XX
is the current sample
size.
4a.
Place
XX
number of items on the scale.
OR
4b.
Press the
SELECT
key repeatedly to scroll through other sample size choices
(1, 2, 5, 10, 25, 50 or 100). When your choice is displayed, place all the
sample on the scale at one time …
buSY
is briefly displayed, followed by one of two possible outcomes:
a. If the sample met the minimum sample requirements and the weight is
stable, the display will show the correct number of parts on the scale
and the
COUNT
annunciator is lit.
OR
If you do not place a sample on the scale within five minutes of selecting the sample
size, the display will show
tmout
(timeout) and return to the gross weight screen.
Minimum sample weight is defined as
0.01% of capacity in dribble mode or 0.02% of
capacity for bulk mode.
Press
SELECT
to see the accumulated count total. The total is erased when a new
piece weight is established, a new PLU is selected or the if the ZK830 is powered off.