95
7
A
PPENDIX
7.1 F
ACTORY
SETTINGS
ALS
350
450
In the case of a memory error:
– The message W__2 or E_12 appears on the
operator panel.
– All databanks are deleted.
– The settings of the machine are reset to fac-
tory settings [93].
Function
Value
Explanation
VELO
0500
Labelling speed: 50.0 m/min
STOD
0000
Distance between dispensing edge and label's leading edge: 0.0 mm
POS
0500
Distance between leading edge of product and label: 50.0 mm
POS2
0000
Multi-labeling: Distance between the leading edges of the first and second la-
bel: 0,0 mm
POS3
0000
Multi-labeling: Distance between the leading edges of the second and third
label: 0,0 mm
VERT
0100
dispensing speed = conveyor belt speed
CONT
0035
Sensitivity of the label stop sensor
LPIT
1000
Label distance = 100.0 mm
E-SS
0016
Distance between label stop sensor and dispensing edge: 16 mm
PRDL
AUTO
Product length = LPIT
P_S_
LEDG
Product sensor: Triggered by leading edge
S_S_
LEDG
Label stop sensor: Triggered by leading edge
MLAB
0000
Machine stops as soon as one product is not labelled
PDT
0000
Label stop = Printer start
PDWT
0000
Printer dwell time: 0.0 s
EGRA
0600
Compensation factor for RPM transmitter for automatic speed adjustment
TMOD
OFF
Tandem operation deactivated
APPL
DIR
Applicator mode deactivated
APT1
0001
EP cylinder dwell time: 1ms
APT2
0001
Blowing time: 1ms
APT3
0000
Delay time: 0ms
APT4
0001
Fine tuning of dwell time: 1ms
MDIR
The last setting remains after a factory reset
OMOD
TAND
0000
Distance between product-sensors during tandem operation: 0.0 mm
SLEW
0055
Dispense speed during missing label compensation: 55 m/min
COMP
ON
Automatic label compensation deactivated
7
A
P P E N D I X
7.1
FACTORY SETTINGS