![Avermedia AVerDiGi MOB1304 NET Скачать руководство пользователя страница 80](http://html1.mh-extra.com/html/avermedia/averdigi-mob1304-net/averdigi-mob1304-net_user-manual_3029901080.webp)
74
(4) Display
-
VGA-TV Selection:
Select the VGA and TV output order.
MAIN - MAIN:
Both VGA and TV output surveillance video on screen.
MAIN
– SPOT:
VGA output surveillance video and TV output the alarm event video.
SPOT
– MAIN:
VGA output alarm event video and TV output the surveillance video.
-
SPOT Mode:
To select the display mode (
QUAD
or
Channel
(1, 2, 3, or 4)) on spot
monitor when there is no alarm event.
-
Auto scan:
Enable/disable auto cycle switch to display the next channel when in full
screen mode.
-
Event Duration:
Select the type of event duration.
-
Set Duration:
Set a time gap (10 ~ 999 seconds) before switch back to preview screen
mode after display the alarm event.
(5) GPS
To enable/disable GPS information message display on surveillance screen.
-
LATITUDE
Enable/disable to display latitude information on surveillance screen.
-
LONGITUDE
Enable/disable to display longitude information on surveillance screen.
-
HEADING
Enable/disable to display heading information on surveillance screen.
-
SPEED OVER GROUND
Enable/disable to display speed information on surveillance screen.
-
Unit
Select the distance format
– KM(kilometer) or MILE
(6) GSM
To setup the GSM numbers for alarm inform if user has enable GSM alarming function in
ALARM SETUP
. Total 5 phone number set can be entered.
-
Name
Assign a name for this GSM number such as administrator
‟s phone number.
-
Phone
Enter the number will be receive the alarm inform when the alarm event has occurred.