2.7.2 Connector Electrical Characteristics
Item
Test Condition
Requirements
Contact Resistance
ANSI/EIA-364-23
20mΩ, maximum, initial per
contact mated pair
10mΩ, maximum change from
original per contact mated pair
Shell Resistance
ANSI/EIA-364-06A-83
Contact resistance measured from
receptacle shell leg to plug cable
braid. Test current = 100mA; Test
Voltage = 5V DC open circuit
maximum
50mΩ, maximum initial
50mΩ, maximum change from
original
Dielectric Withstanding Voltage
ANSI/EIA-364-20
Test voltage 500V DC
V
Method C, unmated and
un-mounted Barometric pressure
of 15 psi
No Flash-over, No Spark-over, No
Excess Leakage, No Breakdown
Insulation Resistance
ANSI/EIA-364-21
Test voltage 500V DC
V
Method C, unmated and
un-mounted
1GΩ minimum between adjacent
contacts and contacts and shell
Contact Current Rating
ANSI/EIA-364-70, TP-70
55°C, maximum ambient
85°C, maximum temperature
change
1.5A minimum
Applied Voltage Rating
40V AC(ms) continuous maximum,
on any signal pin with respect to
the shield
Electrostatic Discharge
IEC 801-2
Test un-mounted from 1kV to 8kV
in 1kV steps using 8mm ball probe
No evidence of discharge to
contacts. Discharge to the shell is
acceptable.