background image

www.avenview.com 

 

1.3

 

Regulatory Notices Federal Communications Commission (FCC) 

 

This equipment has been tested and found to comply with Part 15 of the FCC rules. These limits are designed 
to provide reasonable protection against harmful interference in a residential installation.   
Any changes or modifications made to this equipment may void the user’s authority to operate this 
equipment. 

 

1.4

 

Introduction 

 

Avenview FO-DVI-1000M-EMIX DVI Extender over Fiber lets you extend digital flat panel signal up to 500 
meters (1650 feet) at 1920 x 1200 and 1000 meters (3300 feet) at 1280 x 1024 away from host by TMDS digital 
signal and EDID transmission with only 1 fiber. 

-

 

High Speed and long distance transmission by SC type Multi-Mode 1 fiber 

-

 

R, G, B, Clock signal is transmitted by 1 Multi-Mode optical Fiber   

-

 

EDID data is transmitted by 1 Multi-Mode optical Fiber 

-

 

Supports 12bit deep color   

-

 

Standard DVI plug and SC Fiber connector 

-

 

Supports up to WUXGA (1920 x 1200) resolution 

-

 

HDCP compliant 

-

 

Optional external power supply (Automatic Power switch is included) 

1.5

 

Package Contents 

 

Before you start the installation of FO-DVI-1000M-EMIX, please check the package contents. 

-

 

Transmitter     

 

 

x 1 

-

 

Receiver     

 

 

x 1 

-

 

Power Adapter (5VDC, 2A)  

x 1 

User’s Manual 

 

 

x 1

 

1.6

 

Before Installation 

 

 

Put the product in an even and stable location. If the product falls down or drops, it may cause an 
injury or malfunction. 

 

Don’t place the product in too high temperature (over 50°C), too low temperature (under 0°C) or high 
humidity.   

 

Use the DC power adapter with correct specifications. If inappropriate power supply is used then it 
may cause a fire. 

 

Do not twist or pull by force ends of the optical cable. It can cause malfunction. 

 

Содержание FO-DVI-1000M-EMIX

Страница 1: ...ions and product descriptions at any time without notice No license whether express implied or otherwise to any intellectual property rights is granted by this publication Except as set forth in Avenv...

Страница 2: ...ns Commission FCC 4 1 4 Introduction 4 1 5 Package Contents 4 1 6 Before Installation 4 1 7 Installation 5 1 8 Troubleshooting 5 1 9 Caution 6 Section 2 Specifications 7 2 1 Case Dimensions 8 2 2 Abso...

Страница 3: ...Instructions The Avenview FO DVI 1000M EMIX DVI Extender over Fiber Optic has been tested for conformity to safety regulations and requirements and has been certified for international use However li...

Страница 4: ...Clock signal is transmitted by 1 Multi Mode optical Fiber EDID data is transmitted by 1 Multi Mode optical Fiber Supports 12bit deep color Standard DVI plug and SC Fiber connector Supports up to WUXG...

Страница 5: ...tect the resolution of the monitor and change the resolution accordingly Follow these steps for connecting to a device 1 Power on your Display 2 Connect Transmitter to the DVI Source and Receiver to t...

Страница 6: ...may get damaged 3 Keep away from high temperature over 50 C low temperature under 0 C or high humidity It may cause a fire and injury by electrical shock 4 Use DC power adapter with correct specificat...

Страница 7: ...1200 700 meters 2300 feet SXGA 1280 x 1024 1000 meters 3300 feet Optical Converter 4 Ch 850 nm Transmit OSA 911nm 1 Ch VCSEL 980nm 1 Ch PIN P D Diode 4 Ch 850 nm Transmit OSA 911nm 1 Ch VCSEL 980nm 1...

Страница 8: ...www avenview com 8 2 1 Case Dimensions...

Страница 9: ...nded High Level Input Voltage VH VREF 0 01 VREF 0 01 V Signal ended Low Level Input Voltage VL VREF 0 6 VREF 0 4 V Signal ended Input Swing Voltage VISWING 0 4 0 6 V Signal ended Standby Input Voltage...

Страница 10: ...RLD 50 2 4 Signal Pin Assignment Transmitter Receiver Pin Signal Assignment Pin Signal Assignment Pin Signal Assignment 1 T M D S Data2 9 T M D S Data1 17 T M D S Data0 2 T M D S Data2 10 T M D S Data...

Страница 11: ...www avenview com 11 2 5Optical Fiber Cable The construction of 4 Optical Fibers and 4 Copper wires cable shall be in accordance with Figure and Table below...

Страница 12: ...atory profits or for punitive incidental or consequential damages in connection with the furnishing performance or use of the Avenview hardware software or other products and documentation provided he...

Отзывы: