Figure 3: Typical Valve Wiring Connections 

Содержание SuperSpool RCV

Страница 1: ...the railcar hopper door market for over 30 years Designed around the same spool and seal design that has proven itself for dec ades this valve now offers integrated solenoid opera tors and wire way a simpli fied sub base that allows mounting to most in service stock mounting risers a latching protection cover and provides cost savings to the car owner without sacrificing critical design features O...

Страница 2: ...positioned in such a manner that they cannot be accidentally operated Installation Before installing the SuperSpool RCV Valve all air lines in the system should be blown clean to remove any moisture or loose material To further ensure long trouble free service an efficient air line filter should be installed on the supply side of the valve Since this application has a very low cycle rate an air li...

Страница 3: ... insect excluder may be installed if desired but care should be taken to assure that it is the free flow type and that it is not a design that will clog up with coal dust over time Flow re striction at the exhaust port will slow the speed of the cylinder and door actuation so due caution is suggested if any of these items are installed Operation Temperature Range 20 deg F to 160 deg F Max Operatin...

Страница 4: ... and clean the sole noid end covers in similar fashion to remove dust and debris Rinse and dry these parts thoroughly before reassembly Replace any parts that are damaged or worn giving particular attention to the spool and seal rings Repair kit part numbers are identified on page 6 Lubri cate all rubber parts the bore of the valve body and the spool itself with the Shell Alvania EP RO grease as p...

Страница 5: ... fits all valves R434000524 24 VDC Solenoid Operator Assembly fits either end 2 per valve req d R434000104 Replacement Spool R434008046 A End Detented Operator Body Assembly including Solenoid Operator R434000524 R434000096 B End Solenoid Operator Body Assembly including Solenoid Operator R434000524 R434000743 Sub base and Sub base Gasket Complete Valve less sub base Consult Factory for part numbe...

Страница 6: ...Page 6 2 Typical Valve Exploded View ...

Страница 7: ...Page 7 Figure 3 Typical Valve Wiring Connections ...

Страница 8: ...orking conditions All AVENTICS products should provide a minimum of 1 000 000 cycles of maintenance free service when used and lubricated as recommended However these products should be visually inspected for defects and given an in system operating performance and leakage test once a year Where devices require a major repair as a result of the one million cycles one year or routine inspection the...