Technical data
60
AVENTICS
| ED12 | R414002587–BDL–001–AB
12 Technical data
Air is audibly escaping
Base plate seal is missing or
damaged
Check the base plate seal and
exchange, if necessary
Leaks between the ED12 and
base plate
Tighten screws with 6 Nm torque.
ED12 is not leaktight
Exchange the ED12
Pneumatic connections on the
base plate exchanged
Connect the pneumatics on the base
plate correctly (see “Connecting the
base plate pneumatics” on page 52)
ED12 does not exhaust
Exhaust connection on the base
plate is closed
Open the exhaust connection and
connect a silencer or restricted
exhaust hose
ED12 emits short pressure
pulses
Device with current input is
operated with voltage set point
Stipulate the correct type of set point
Table 12:
Malfunction
Possible cause
Remedy
Table 13:
General
Dimensions (width x height x depth)
254 mm x 100 mm x 55 mm
Weight
2.3 kg
Operating temperature range
5
°
C to 50
°
C
Storage temperature range
–20
°
C to +80
°
C
Controlling
Analog
Model
Poppet valve
Permissible medium
Air with quality class DIN ISO 8573-1
For solid impurities:5
For water content:3
For total oil content:1