Page 7

 

 

IDENTITY SCHEDULE

 

 

*H

-

1 Control Portion part number is less pipe bracket, pedal operator portion and mounting screws. 

 

See pages 8 & 9 for control portions item numbers and parts list. See page 10 for pipe bracket and 

 

operator item numbers and parts list.

 

 

Note 1:

 

Same as H

-

1 Type R431002613 (P 

-

050208

-

00001) except light pedal spring R431005474 

 

 

 

(P 

-

060294

-

00000), item 5, page 8

 

Note 2:

 

Same as H

-

1 Type R431002614 (P 

-

050208

-

00002) except light pedal spring R431005474 

 

 

(P 

-

060294

-

00000), item 5, page 8

 

Note 3:

 

With full pressure feature (consult factory for (P 

-

065316

-

00000) parts).

 

Note 4:

 

With rubber tread (light pedal force).

 

Note 5:

 

Same as H

-

1 Type R431003063  (P 

-

052971

-

00001) except less pedal, items 7, 8, and 9, page 10

 

 

Model

 

New 

 

Complete

 

Part 

 

Number

 

Old 

 

Complete

 

Part 

 

Number

 

Control 

 

Pressure 

Range 

 

(PSI)

 

Control 

Spring 

 

New Part 

Number

 

Control 

 

Spring 

 

Old Part 

 

Number

 

Valve 

 

Portion

 

New  

 

Number

 

Valve

 

Portion

 

Old Part

 

Number

 

 

Remarks

 

H

-

1

 

R431002613

 

-

050208

-

00001

 

0

-

65 psi

 

R431003732

 

-

055442

-

00000

 

R431002874

 

-

051133

-

00001

 

 

H

-

1

 

R431002614

 

-

050208

-

00002

 

0

-

100 psi

 

R431000043

 

-

526749

-

00000

 

R431002875

 

-

051133

-

00002

 

 

H

-

1

 

R431002615

 

-

050208

-

00003

 

0

-

125 psi

 

R431000099

 

-

540577

-

00000

 

R431002876

 

-

051133

-

00003

 

 

H

-

1

 

R431002616

 

-

050208

-

00004

 

0

-

150 psi

 

R431003731

 

-

055441

-

00000

 

R431002877

 

-

051133

-

00004

 

 

H

-

1

 

R431002617

 

-

050208

-

00008

 

0

-

30 psi

 

R431005475

 

-

060295

-

00000

 

R431002878

 

-

051133

-

00008

 

 

H

-

1

 

R431002822

 

-

050967

-

00008

 

0

-

65 psi

 

R431005475

 

-

060295

-

00000

 

R431002878

 

-

051133

-

00008

 

 

H

-

1

 

R431002981

 

-

052570

-

00001

 

0

-

100 psi

 

R431003732

 

-

055442

-

00000

 

R431002874

 

-

051133

-

00001

 

Note 1

 

H

-

1

 

R431002982

 

-

052570

-

00002

 

0

-

65 psi

 

R431000043

 

-

526749

-

00000

 

R431002875

 

-

051133

-

00002

 

Note 2

 

H

-

1

 

 

-

065292

-

0000

 

0

-

35 psi

 

R431005475

 

-

060295

-

00000

 

 

-

057182

-

00008

 

Note 3

 

H

-

1

 

R431005617

 

-

060921

-

00001

 

0

-

65 psi

 

R431003732

 

-

055442

-

00000

 

R431002874

 

-

051133

-

00001

 

Note 4

 

H

-

1

 

R431005618

 

-

060921

-

00002

 

0

-

100 psi

 

R431000043

 

-

526749

-

00000

 

R431002875

 

-

051133

-

00002

 

Note 4

 

H

-

1

 

R431005619

 

-

060921

-

00003

 

0

-

125 psi

 

R431000099

 

-

540577

-

00000

 

R431002876

 

-

051133

-

00003

 

Note 4

 

 

 

 

 

 

 

 

 

 

H1

-

A

 

R431003063

 

-

052971

-

00001

 

0

-

65 psi

 

R431003732

 

-

055442

-

00000

 

R431002850

 

-

051085

-

00001

 

 

H1

-

A

 

R431003064

 

-

052971

-

00002

 

0

-

100 psi

 

R431000043

 

-

526749

-

00000

 

R431002851

 

-

051085

-

00002

 

 

H1

-

A

 

R431003065

 

-

052971

-

00003

 

0

-

125 psi

 

R431000099

 

-

540577

-

00000

 

R431002852

 

-

051085

-

00003

 

 

H1

-

A

 

R431003066

 

-

052971

-

00004

 

0

-

150 psi

 

R431003731

 

-

055441

-

00000

 

R431002853

 

-

051085

-

00004

 

 

H1

-

A

 

Obsolete

 

-

052971

-

00008

 

0

-

30 psi

 

R431005475

 

-

060295

-

00000

 

R431002855

 

-

051085

-

00008

 

 

H1

-

A

 

Obsolete

 

-

064701

-

00001

 

0

-

65 psi

 

R431003732

 

-

055442

-

00000

 

R431002850

 

-

051075

-

00001

 

Note 5

 

Содержание CONTROLAIR H-1

Страница 1: ...ons in which its operator is standing or in which part of the valve cannot extend below floor levels Depressing its pedal increases the outlet delivery pressure Releasing the pedal decreases the outlet delivery pressure The pedal is self returning Table of Contents Page Description of Models 1 Technical Data 2 Installation 2 Maintenance and Repair 2 Outline Dimensions H 1 3 Outline View 4 5 Descri...

Страница 2: ...air is required the valve must be removed repaired and tested A major overhaul is recommended at one million cycles However where frequency of use is such that it would require more than two years to obtain one million cycles the valve must be overhauled at the two year period When it is determined that the Controlair Valve requires a major repair as a result of the one million cycles one year rou...

Страница 3: ...Page 3 H 1 CONTROLAIR VALVES OUTLINE DIMENSIONS ...

Страница 4: ...H 1 CONTROLAIR VALVE LIGHT PEDAL FORCE OUTLINE VIEW Page 4 ...

Страница 5: ...H 1 A CONTROLAIR VALVES OUTLINE VIEW Page 5 ...

Страница 6: ...contour and is therefore proportional to the pedal travel The Controlair Valve will automatically compensate for downstream air pressure changes in the graduated pressure delivery line These air pressure changes can be caused by line leakage temperature change or load feedback If air pressure at the outlet port increases over that called for by pedal position the diaphragm in the control portion w...

Страница 7: ...31002616 P 050208 00004 0 150 psi R431003731 P 055441 00000 R431002877 P 051133 00004 H 1 R431002617 P 050208 00008 0 30 psi R431005475 P 060295 00000 R431002878 P 051133 00008 H 1 R431002822 P 050967 00008 0 65 psi R431005475 P 060295 00000 R431002878 P 051133 00008 H 1 R431002981 P 052570 00001 0 100 psi R431003732 P 055442 00000 R431002874 P 051133 00001 Note 1 H 1 R431002982 P 052570 00002 0 6...

Страница 8: ...03892 P 055687 00000 page 11 H 1 H 1 A Part No R431002608 P 050138 00000 Spring Housing Complete Includes No 1 and 2 1 2 3 4 5 12 11 10 8 9 15 14 14 13 7a 6a 17 18 6 16 22 7 20 23 20 19 21 H 1 Light Pedal R431005617 P 060921 00001 Series EXPLODEDVIEW Part No R431003714 P 055409 00000 Diaphragm with Exhaust Valve Seat Complete Includes No 8 9 10 11 12 ...

Страница 9: ...21 a See 21 a P 066209 00000 P 066488 00002 P 049901 00020 526347 00000 See Page 7 526874 00000 850577 00000 P 055409 00000 See Repair Kits See Repair Kits See Repair Kits See Repair Kits See Repair Kits See Repair Kits See Repair Kits See Repair Kits See Repair Kits See Repair Kits See Repair Kits See Repair Kits See Repair Kits See Repair Kits See Repair Kits See 21a See 21a See 21a P 066209 000...

Страница 10: ...crews R431002291 P 049842 00000 2 1 Pipe bracket R431006911 P 066888 00000 3 2 5 16 18 x 1 bolts R431002227 P 049832 00064 4 2 5 16 Washers R431002419 P 049901 00020 5 2 5 16 18 Nuts R431005527 P 060397 00001 Pedal portion incl 6 15 P 060397 00001 6 1 Mounting bracket 7 2 Retaining rings 8 1 Pins 9 1 Spring R431005504 P 060384 00000 10 1 Screw minimum pressure 11 1 Locknut 12 1 Screw minimum press...

Страница 11: ...Part No 2008 Complete pedal kit with pipe bracket and standard springs for H 1 P 051090 00000 P 051090 K0002 R431002865 New replacement pedal and pin kit for H 1 520474 P 026205 00000 R431000597 Part Number Quantity Per Valve Description R431003895 P 055687 K0000 1 Minor graduating valve portion repair kit includes items 8 9 10 11 12 13 14 see note R431004887 P 059028 K0000 1 Major graduating valv...

Страница 12: ...d that the Controlair Valve requires shop repairs see page 2 for general maintenance and repair recommendations the following general instructions are recommended Disassembly Cleaning and Lubrication Complete disassemble the Controlair Valve Wash all metal parts in a non flammable solvent Rinse each part thoroughly and blow dry with a low pressure air jet Arrange the parts on a clean surface Inspe...

Страница 13: ...e rated maximum pressure setting always be sure the delivered pressure goes to zero upon release of the pedal 6 The inability to complete the above adjustments on a repaired valve would indicate the following possibilities Pedal cam roller and or eccentric pin is worn past the point where step 2 can be completed Replace as necessary Incorrect control spring for the range desired check the spring i...

Страница 14: ...permitted in any pedal position A On all valves with spring ranges less than 100 psi set supply lines pressure to 100 psi Depress pedal to full travel position and hold Close valve in sup ply line to IN port and valve in delivery line from OUT delivery line pressure gage A pressure drop of no more than 2 psi in 30 seconds is permitted B On all valves with spring ranges 100 psi and above set supply...

Страница 15: ...ct the flow If quick couplers are used be sure they are full flow or oversize 3 It is recommended that as large of a gauge as practical be used on the delivery lines A 6 gauge is recommended Test Valve H 1 Light Pedal Shown H 1 and H 1 A Connected Similar 1 4 PIPE SCHEDULE 40 OR 3 8 O D TUBING OR 6 SINGLE BRAID HOSE P N PD 020031 00191 AVENTICS P N R432016359 PR 007816 00010 PRESSURE GAGE IN OUT C...

Страница 16: ...intenance periods should be scheduled in accordance with frequency of use and working conditions All AVENTICS products should provide a minimum of 1 000 000 cycles of maintenance free service when used and lubricated as recommended However these products should be visually inspected for defects and given an in sys tem operating performance and leakage test once a year Where devices require a major...

Страница 17: ......